موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
الرئيسية / المنتجات / Containment & Biosafety Equipment / Negative-Pressure Containment Isolator 4-Glove with One Airlock
STJH-NEGATIVE-PRESSURE-CONTAINMENT-ISOLATOR-4G-1AL

Negative-Pressure Containment Isolator 4-Glove with One Airlock

An extended four-glove containment isolator with one shared material airlock for long instrument trains or multi-stage potent processing.
  • 1985 mm extended work zone
  • Four glove positions
  • One large transfer airlock
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The four-glove chamber increases the internal working width to 1985 mm while retaining one transfer airlock. It suits processes in which several instruments or consecutive manipulation steps must remain inside a continuous negative-pressure zone, but material entry and exit can share the same interchange under procedural control.

الخصائص الرئيسية

Long process deck

Four access positions distribute weighing, processing and pack-off tasks across one sealed chamber.

Shared transfer footprint

A single airlock limits overall width compared with a dual-airlock system while accepting larger staged loads.

Configurable toxic operation

Pressure, filtration and utilities can be arranged for formulation or aseptic-toxic laboratory work.

المعلمات الفنية

Work-Zone Dimensions1985 x 715 x 629 mm
Overall Dimensions2683 x 955 x 2277 mm with one airlock
Glove Ports4 process glove positions
Transfer ArrangementOne large material airlock
Operating PressureApproximately -60 Pa negative-pressure mode
FiltrationDouble HEPA exhaust arrangement
Chamber ConstructionStainless steel work area and transfer airlock
Power Supply220-240 V AC, 50-60 Hz, up to 3800 W
Control PlatformPLC control with local touchscreen
التخصيصAirlock orientation, glove spacing, utilities and internal process fixtures can be adapted to the intended operating sequence.

Applications

Multi-step HPAPI formulation, extended analytical equipment trains, contained subdivision and aseptic-toxic processing requiring four direct manipulation positions.

Solutions for Your Application

A long process train is difficult to reach from only two glove ports.Four access positions span the 1985 mm chamber so instruments can be assigned to distinct handling zones.
The room cannot accommodate separate infeed and outfeed airlocks.Use the single-airlock architecture and manage bidirectional transfers through a defined batch sequence.

الخيارات المتاحة

Large-load airlock fittings, glove selection, H2O2 cycle equipment, balances, service connections and monitoring interfaces are configurable.

Planning a Negative-Pressure Containment Isolator 4-Glove with One Airlock specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat

الرئيسية

المنتجات

الأخبار

من نحن

اتصل بنا