الرئيسية / المنتجات / معدات الغرف النظيفة / Fan Filter Unit 410 × 416 mm 24 VDC Low-Voltage
STJH-LOW-VOLTAGE-DC-FFU-410X416-24V

Fan Filter Unit 410 × 416 mm 24 VDC Low-Voltage

A medium-format DC filter unit with five airflow settings for adjustable air delivery across an equipment loading area.
  • Five airflow settings
  • Replaceable HEPA element
  • Equipment loading area
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The 410 mm housing carries a replaceable HEPA element within a compact fan assembly. Its larger outlet bridges the gap between an individual instrument cover and a wider process enclosure, while the separate operating and airflow controls support routine adjustment. The nominal 416 mm depth corresponds to a 415.5 mm casing dimension.

الخصائص الرئيسية

Five discrete settings

Five discrete settings allow intermediate air delivery rather than an all-or-nothing increase.

Defined replacement size

A 350 x 350 x 50 mm filter format provides a defined replacement size for maintenance planning.

Removable intake prefilter

A removable intake prefilter catches larger airborne debris before it reaches the final filter.

المعلمات الفنية

Casing Dimensions410 W x 415.5 D x 150 H mm
Power Supply24 VDC
Motor TypeBrushless DC motor
Airflow SettingsFive steps: approximately 3.4 / 3.0 / 2.5 / 2.0 / 1.0 m³/min
Nominal Discharge VelocityApproximately 0.52 / 0.46 / 0.38 / 0.31 / 0.15 m/s, from highest to lowest setting
Power ConsumptionApproximately 41 / 32 / 26 / 20 / 10 W in descending airflow order
Main FilterHEPA, 350 x 350 x 50 mm; nominal collection efficiency at least 99.99% at 0.3 µm
PrefilterServiceable polymer mesh on the intake
Casing MaterialMoulded antistatic ABS
التخصيصThe mounting interface and cable arrangement can be adapted to the loading station and its operating environment.

Applications

Filtered make-up air for a compact semiconductor equipment loading enclosure. Overhead supply to a covered parts buffer beside an assembly process.

Solutions for Your Application

The loading area needs more air during active transfer than while parts are waiting.Select an intermediate or higher fan position for the established operating condition, then use the lower position when the process permits.
Routine filter service could require dismantling the surrounding machine guard.Arrange accessible filter withdrawal space and keep the intake mesh reachable when positioning the housing.

الخيارات المتاحة

ULPA filtration in place of the standard HEPA arrangement. A DC connection lead matched to the equipment power supply.