الرئيسية / المنتجات / Cleanroom HVAC Systems / Chilled-Water Cooling Coil Eight-Row 5/8-Inch
STJH-CHILLED-WATER-COOLING-COIL-8ROW-58IN

Chilled-Water Cooling Coil Eight-Row 5/8-Inch

The deepest selected water coil for high-latent make-up air and low leaving-temperature duty.
  • Eight-row deep core
  • 6-72 in fin-height range
  • High-latent cooling duty
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The eight-row core provides the longest air path and largest surface area in this chilled-water group. The referenced construction spans fin heights from 6-72 in and lengths from 12-240 in, allowing large custom faces for low-temperature supply air. Its added latent capacity suits high outdoor-air fractions, but the designer must account for greater wet pressure drop, condensate volume and cleaning access.

الخصائص الرئيسية

Maximum heat-transfer depth

Eight rows support lower leaving temperatures and greater moisture removal than the shallower models.

Wide custom face range

Published height and length ranges support both compact and very large AHU sections.

Make-up-air capability

The deep surface is appropriate for high outdoor-air latent loads and low dew-point supply.

المعلمات الفنية

Tube Rows8
Tube Outside Diameter5/8 in
Fin Height Range6-72 in
Fin Length Range12-240 in
Tube MaterialCopper by standard duty
Fin MaterialAluminum by standard duty
FluidChilled water
CasingSelected for wet AHU environment
Primary DutyHigh-latent and low-temperature supply air
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

Applications

For high-outdoor-air cleanroom make-up units, low-dew-point supply systems and precision spaces with demanding latent loads.

Solutions for Your Application

The deep coil and dense fins exceed the supply fan's available static pressure.Rate wet and dry resistance at actual face velocity and enlarge the face or reduce fin density where needed.
Condensate remains inside the eight-row core after shutdown.Provide full-depth drainage, correct coil pitch and access for cleaning the entering and leaving faces.

الخيارات المتاحة

Specify face size, leaving conditions, water temperatures, fin spacing, tube wall, circuiting, coating, casing and moisture eliminator.