الرئيسية / المنتجات / Cleanroom HVAC Systems / Chilled-Water Cooling Coil Six-Row 5/8-Inch
STJH-CHILLED-WATER-COOLING-COIL-6ROW-58IN

Chilled-Water Cooling Coil Six-Row 5/8-Inch

A medium-depth wet coil providing greater total and latent capacity than a four-row core for central cleanroom AHUs.
  • Six-row dehumidification core
  • 6-14 fins per inch
  • Galvanized or stainless casing
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

This six-row configuration adds two full tube rows beyond the shallow model, increasing surface contact and latent-cooling potential. Five-eighth-inch tubes, 6-14 fins per inch and galvanized or stainless casing options allow it to be rated for general cleanroom cooling and dehumidification. The coil is a balanced central-AHU choice when four rows are insufficient but an eight-row low-temperature core would consume unnecessary fan static.

الخصائص الرئيسية

Greater latent capacity

Two additional rows extend air contact with the cold surface for more moisture removal.

Configurable fin density

Fin spacing can be balanced against heat transfer, fouling risk and pressure drop.

Wet-service casing choice

Stainless construction can be selected for humid or frequently cleaned AHU sections.

المعلمات الفنية

Tube Rows6
Tube Outside Diameter5/8 in
Tube MaterialCopper
Fin Density6-14 fins per inch
Fin MaterialAluminum by standard selection
CasingGalvanized or stainless steel
FluidChilled water
Condensate ManagementFull drain pan required
Primary DutyGeneral cooling and dehumidification
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

Applications

For central cleanroom AHUs serving pharmaceutical, electronics and controlled production areas with combined sensible and latent loads.

Solutions for Your Application

The deeper wet coil accumulates biological soil between close fins.Select cleanable fin spacing, provide upstream filtration and preserve access for inspection and washing.
Water circuiting produces poor low-load control and unstable leaving temperature.Match circuits and control valve authority to the design flow and turndown requirement.

الخيارات المتاحة

Confirm face dimensions, cooling and latent load, water flow, fin spacing, tube wall, circuits, coating, casing and drain-pan material.

Planning a Chilled-Water Cooling Coil Six-Row 5/8-Inch specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat