STJH-STERILITY-TEST-ISOLATOR-1600-3G

Sterility Test Isolator 1600 mm Three-Glove

A mid-width sterility-test isolator with three glove positions and added staging room for routine multi-sample quality-control work.
  • 1600 mm chamber width
  • Three manipulation positions
  • Multi-sample staging
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

The 1600 mm internal chamber introduces a third manipulation position and 400 mm more work width than the compact model. It gives operators room to separate incoming samples, active test handling and completed items while retaining the same filtration concept as the family.

Các tính năng chính

Intermediate work capacity

The chamber accommodates routine batches without moving directly to the largest four-glove enclosure.

Three-zone reach pattern

Three glove positions can support distinct preparation, testing and output areas along the work surface.

Documented airflow choices

Published total-exhaust and recirculating airflow values support facility utility planning.

Thông số kỹ thuật

Internal Process Chamber1600 x 540 x 700 mm
External Process-Chamber Envelope1904 x 881 x 2430 mm
Glove Ports3
Supply FilterU15, nominal 99.9995% at MPPS
Exhaust FilterH14, nominal 99.995% at MPPS
Total-Exhaust Airflow1363 m³/h
Recirculating Airflow680 m³/h
Work-Zone FunctionPreparation, active test and staging positions
Relative Family SizeIntermediate standard chamber
Tùy chỉnhMaterial transfer, pump location and process monitoring can be configured for the sample workflow.

Applications

Routine multi-sample sterility testing, pharmaceutical microbiology quality control and aseptic test-kit handling that benefits from three access positions.

Solutions for Your Application

Samples and consumables become mixed within a two-position chamber.Use the third glove position to establish a separate staging zone and maintain directional material movement.
The facility must size exhaust for a larger process volume.Use the documented 1363 m³/h total-exhaust or 680 m³/h recirculating value when reviewing the selected architecture.

Các tùy chọn có sẵn

Transfer chambers, integrated pump location, tray organization and environmental monitoring interfaces can be selected for the testing protocol.

Planning a Sterility Test Isolator 1600 mm Three-Glove specification?

Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.

Nói chuyện với đội ngũ của chúng tôi
Email cho chúng tôi WhatsApp WeChat

Trang chủ

Sản phẩm

Tin tức

Về chúng tôi

Liên hệ