Nhà cung cấp một cửa của bạn cho thiết bị phòng sạch và thiết bị vô trùng cơ sở thiết yếuHỗ trợ dự án quốc tế
Open mobile navigationClose mobile navigation
Trang chủ / Sản phẩm / Thiết bị phòng sạch / Negative-Pressure Containment Pass Box 500 mm
STJH-NEGATIVE-PRESSURE-CONTAINMENT-PASS-BOX-500

Negative-Pressure Containment Pass Box 500 mm

A compact stainless chamber that maintains airflow from the clean side toward the contaminated side during small-load transfer.
  • 500 mm contained work zone
  • Clean-to-contaminated airflow direction
  • 1.2 mm SUS304 chamber
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

This smallest negative-pressure model combines a 500 mm cubic work zone with a 660 x 500 x 590 mm external envelope. The 1.2 mm SUS304 enclosure uses a mechanical door interlock and controlled clean-to-contaminated airflow direction. It is intended for small contained articles leaving a clean area where inward leakage direction matters more than active positive-pressure protection of the load.

Các tính năng chính

Compact contaminated-side bias

The airflow direction is arranged toward the contaminated side to discourage release back into the cleaner room.

Small partition demand

The 660 mm external width preserves wall space around densely serviced laboratory rooms.

Simple mechanical sequencing

A mechanical interlock prevents simultaneous access without depending on an electronic door-control package.

Thông số kỹ thuật

Work Zone500 W x 500 D x 500 H mm
External Dimensions660 W x 500 D x 590 H mm
Primary Material1.2 mm SUS304 stainless steel
Pressure ModeNegative-pressure containment
Airflow DirectionClean side toward contaminated side
Door InterlockMechanical
Door ArrangementOpposed transfer doors
Interior GeometrySmooth stainless transfer chamber
Intended Load ClassSmall closed samples and contained items
Tùy chỉnhCó sẵn dựa trên ứng dụng dự định và môi trường hoạt động.

Applications

For compact laboratory samples, sealed diagnostic packs and controlled waste moving away from a clean pharmaceutical, hospital or research space. The facility exhaust strategy and actual pressure relationship must be reviewed so the stated clean-to-contaminated direction agrees with the room cascade.

Solutions for Your Application

A positive-pressure pass box could push air in the wrong direction when the transferred item is the contamination source.Select the negative-pressure configuration so leakage is biased from the cleaner side toward the contaminated side.
A large active chamber would occupy excessive wall area for low-volume specimen transfer.Use the 500 mm work zone for compact loads and verify the complete load envelope before freezing the cut-out.

Các tùy chọn có sẵn

Define exhaust connection, pressure monitoring, door handing, window arrangement and wall trim for the facility. Load disinfection and downstream waste handling remain part of the user's containment procedure.

Planning a Negative-Pressure Containment Pass Box 500 mm specification?

Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.

Nói chuyện với đội ngũ của chúng tôi
Email cho chúng tôi WhatsApp WeChat

Trang chủ

Sản phẩm

Tin tức

Về chúng tôi

Liên hệ