Trang chủ / Sản phẩm / Cleanroom Air Filters / Cylindrical Chemical Filter Cartridge 148 × 452 mm
STJH-CHEMICAL-FILTER-CARTRIDGE-148X452

Cylindrical Chemical Filter Cartridge 148 × 452 mm

A medium-length molecular cartridge balancing media mass, handling weight and standard AHU airflow.
  • 452 mm medium length
  • 2500 m3/h bank rating
  • Selectable chemical media
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

The 452 mm cylinder provides more adsorbent volume and doubles the documented bank airflow of the compact 240 mm format. A sixteen-cartridge arrangement handles about 2500 m3/h, with a 100-150 Pa initial resistance determined by the chosen media. This mid-size configuration is suited to standard air handlers that need useful gas capacity but do not have the withdrawal depth or fan static required by the longest cartridge.

Các tính năng chính

Balanced service size

The intermediate length adds media while retaining manageable cartridge removal and storage.

Standard AHU capacity

Sixteen cylinders provide a documented 2500 m3/h gas-phase stage for common equipment sizes.

Media-specific resistance

The stated pressure range allows fan selection to account for the actual adsorbent blend.

Thông số kỹ thuật

Cylinder Diameter148 mm
Cylinder Length452 mm
Bank Airflow2500 m3/h for 16 cartridges
Initial Pressure Drop100-150 Pa depending on media
Media OptionsVOC, acids, bases, sulfur compounds or mixed gas
Mounting InterfaceTwist-lock cartridge plate
InstallationStandard molecular-filter housing
Particle ControlSeparate upstream prefilter
Service CriterionCapacity calculation and outlet monitoring
Tùy chỉnhCó sẵn dựa trên ứng dụng dự định và môi trường hoạt động.

Applications

For cleanroom make-up units, industrial recirculation, laboratory ventilation and standard AHU gas-phase stages with moderate contaminant loads.

Solutions for Your Application

Operators cannot tell when molecular media is exhausted because pressure drop remains stable.Set changes from calculated exposure, media samples or downstream gas readings instead of waiting for a resistance alarm.
Some cylinders receive more air because the bank inlet is poorly distributed.Provide a uniform inlet plenum and verify that every bayonet cartridge and blanking position is sealed.

Các tùy chọn có sẵn

Confirm gas analysis, media blend, bank count, target airflow, pressure allowance, cabinet finish, prefilter and sampling access.

Planning a Cylindrical Chemical Filter Cartridge 148 × 452 mm specification?