Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Ana Sayfa / Ürünler / Temiz Oda Ekipmanları / Personnel Misting Shower 750 × 940 mm Compact
STJH-PERSONNEL-MISTING-SHOWER-750X940

Personnel Misting Shower 750 × 940 mm Compact

A compact stainless misting chamber for single-person garment decontamination in potent-powder exits.
  • 750 x 940 mm compact interior
  • 6 bar mist-air supply
  • SS304 interlocked chamber
Alıntı isteği Browse ürünleri

Ürün tanıtımı

The smallest mist-shower model provides a 750 x 940 x 1800 mm interior within a 1150 x 1000 x 2000 mm shell. Precision nozzles use a 6 bar compressed-air supply to create fine droplets that bind surface and airborne powder on garments. SS304 construction, interlocked doors and more than 400 lux lighting support a controlled single-station exit where a large chamber is not required.

Ana Özellikler

Small HPAPI exit footprint

The one-metre external depth fits a compact personnel decontamination airlock.

Fine-droplet particle capture

Mist wets loose garment contamination so fine powder is less likely to become airborne during the next exit step.

Controlled access sequence

Electromagnetic interlocks separate entry and exit during the programmed mist cycle.

Teknik parametreler

Interior Dimensions750 W x 940 D x 1800 H mm
Exterior Dimensions1150 W x 1000 D x 2000 H mm
ConstructionSS304 stainless steel
Alternative MaterialSS316 optional
Compressed Air6 bar
Lighting>400 lux
Door ControlElectromagnetic interlocks
Misting ProcessFine pressurized fog around garments
Power SupplySingle phase or three phase
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Applications

For compact HPAPI exit airlocks, biosafety gowning routes and fine-powder handling suites serving one operative at a time. The process assessment should define mist medium, drainage, drying and subsequent doffing steps.

Solutions for Your Application

Dry air blow-off can re-aerosolize potent powder on protective garments.Use controlled fine mist to bind particles before the operator proceeds to the next decontamination stage.
The facility has room for only a short exit chamber.Select the 1000 mm external depth and preserve separate space for drying or doffing if required.

Mevcut Seçenekler

Specify SS304 or SS316, manual or automatic sliding doors, mist medium, programmable cycle, drainage and optional downstream drying. Compatibility with garments and active compounds must be assessed.

Planning a Personnel Misting Shower 750 × 940 mm Compact specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

Ekibimizle konuşun
E-posta Bize whatsapp WeChat