Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Ana Sayfa / Ürünler / Temiz Oda Ekipmanları / FFU Ceiling Grid 2 × 4 ft Stainless Steel
STJH-FFU-CEILING-GRID-2X4-STAINLESS

FFU Ceiling Grid 2 × 4 ft Stainless Steel

A cleanable 304 stainless ceiling structure for aseptic and washdown-sensitive FFU layouts.
  • 304 stainless steel frame
  • 2 x 4 ft FFU bays
  • ISO 5 design option
Alıntı isteği Browse ürünleri

Ürün tanıtımı

This ceiling grid retains the standard 2 x 4 ft modular bay but replaces coated steel with 304 stainless construction. The exposed frame is easier to integrate into aseptic and washdown-sensitive rooms, and the source lists it as an ISO 5 design option. The surface remains non-walkable, so maintenance traffic requires separate access provisions.

Ana Özellikler

Cleanable exposed metal

Stainless members support frequent compatible wipe-down in sensitive rooms.

Standard equipment pattern

Two-by-four-foot bays coordinate FFUs, lights and closure panels.

Aseptic material choice

The corrosion-resistant frame suits applications where coated steel is less desirable.

Teknik parametreler

Standard Bay Size2 x 4 ft
Frame Material304 stainless steel
Application ClassISO 5 design option
Walking SurfaceNon-walkable
Supported ComponentsFFUs, lights and blank panels
Surface ConditionCleanable stainless finish
Grid LayoutModular rectangular ceiling
SuspensionSized for equipment and frame loads
Perimeter SealConfigured to wall and ceiling interfaces
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Applications

Recommended for aseptic processing, pharmaceutical support and washdown-sensitive cleanrooms requiring stainless exposed surfaces. Cleaning-agent compatibility and ceiling loads should be reviewed together.

Solutions for Your Application

Painted grid members may be unsuitable for frequent aggressive cleaning.Use 304 stainless members and select compatible gaskets and sealants.
Operators could treat the metal grid as walkable.Provide separate maintenance access and retain the non-walkable designation.

Mevcut Seçenekler

Specify finish, suspension, perimeter connection, bay map and sealant system. Structural calculations remain tied to the installed equipment loads.

Planning a FFU Ceiling Grid 2 × 4 ft Stainless Steel specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

Ekibimizle konuşun
E-posta Bize whatsapp WeChat

Ana Sayfa

Ürünler

Haberler

Hakkımızda

İletişim