Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Ana Sayfa / Ürünler / Cleanroom Furniture / Low-Humidity Dry Cabinet
Temiz Oda Mobilyaları ve Paslanmaz Çelik Ürünleri

Düşük nemli kuru kabine

An actively controlled steel dry cabinet that uses automatically regenerated molecular-sieve modules to maintain a stable low-humidity atmosphere around moisture-sensitive components.
  • Active molecular-sieve drying modules
  • Adjustable 1–10% RH setpoint range
  • Static-dissipative glazed doors
  • Digital humidity display and alarms
Alıntı isteği Browse ürünleri

Ürün tanıtımı

The low-humidity dry cabinet combines a sealed powder-coated steel enclosure with twin automatically regenerated molecular-sieve drying modules. Internal air is drawn through the active modules, dried without continuous nitrogen consumption and returned through a rear distribution channel across six adjustable perforated shelves. Three independently accessed glazed door zones reduce the amount of room air introduced during retrieval. A front digital controller displays relative humidity and module status, while conductive shelf supports and a dedicated grounding stud provide a defined path for static charge from stored electronic parts and trays.

Ana Özellikler

Alternating molecular-sieve modules regenerate automatically, allowing one drying path to remain available while the other restores its moisture capacity.

Three separate static-dissipative door zones limit humidity recovery time after a single shelf group is accessed.

A perforated rear return channel distributes dry air across the cabinet height instead of concentrating it around the drying unit.

The digital controller shows measured RH, target setting and high-humidity condition without requiring the cabinet to be opened.

Müşteri Ürün Sorunları

Moisture-sensitive electronic inventory needs repeatable low-RH storage without the gas consumption and access losses associated with a single large door.

Moisture-sensitive packages absorb room humidity between assembly operations.Active molecular-sieve modules continuously remove water vapor and return dry air through the rear distribution channel.
Opening one full-height door raises humidity around every stored reel and tray.Three independently gasketed glazed zones confine each access event to a smaller cabinet volume.
A saturated desiccant pack can stop protecting stock without a visible warning.Automatic regeneration and the external RH controller expose drying status and high-humidity conditions at the front panel.
Very dry air increases the static sensitivity of ungrounded component storage.Conductive shelf supports, static-dissipative glazing and an external grounding stud create a controlled discharge path.

Tipik uygulamalar

Moisture-sensitive semiconductor package storagePrinted circuit board stagingPrecision sensor and optical component holdingAdditive-manufacturing powder container storageElectronic assembly work-in-process protection

Teknik parametreler

Typical configurable specifications for an active low-humidity electronic-component cabinet are listed below.

Temel malzemelerPowder-coated steel sealed enclosure with static-dissipative glazed doors, six conductive perforated shelves and twin regenerated molecular-sieve drying modules
Panel kalınlığı1.2 mm enclosure panels, door frames and rear air-distribution channel
Effective Width (Etkili Genişlik)1200 mm overall cabinet width
Maksimum uzunluk1900 mm maximum overall cabinet height
Çelik yüz yüze kalınlığı1.2 mm powder-coated carbon-steel body, doors and shelf supports
Core Density (Çekirdek Yoğunluğu)7850 kg/m³ for the carbon-steel enclosure
Termal İletkenlik45–60 W/(m·K) for the carbon-steel enclosure
Yüzey bitirmeLight-gray cleanroom powder coat with clear static-dissipative glazing, cobalt-blue drying modules and black conductive shelves
Ortak tipSeam-welded cabinet with three gasketed glazed door zones, magnetic compression closures, sealed rear circulation channel and bolted serviceable drying-module flanges
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Mevcut Seçenekler

1–10% RH or 10–20% RH control rangesTemperature and RH data loggingReel-support or pull-out tray packagesNitrogen backup purge connection

Planning a Low-Humidity Dry Cabinet specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

Ekibimizle konuşun
E-posta Bize whatsapp WeChat

Ana Sayfa

Ürünler

Haberler

Hakkımızda

İletişim