ผู้จัดจําหน่ายแบบครบวงจรสําหรับอุปกรณ์ห้องคลีนรูมและสิ่งจําเป็นสําหรับสิ่งอํานวยความสะดวกปลอดเชื้อการสนับสนุนโครงการระหว่างประเทศ
Open mobile navigationClose mobile navigation
หน้าแรก / ผลิตภัณฑ์ / Cleanroom HVAC Systems / Water-Cooled Centrifugal Chiller 1055 kW
STJH-WATER-COOLED-CHILLER-1055KW

Water-Cooled Centrifugal Chiller 1055 kW

The smallest selected centrifugal configuration, delivering 1055 kW in a 4533 x 2469 x 2852 mm water-cooled package.
  • 1055 kW cooling capacity
  • 150.8 kW published input
  • 4533 mm compact frame length
ขอใบเสนอราคา เรียกดูสินค้า

การแนะนําสินค้า

This 1055 kW configuration uses the most compact selected 19DV envelope and a published 150.8 kW input. DN300 evaporator and DN250 condenser connections serve a medium central plant where water-cooled efficiency and a smaller equipment footprint are priorities.

คุณสมบัติที่สําคัญ

Compact centrifugal platform

The shortest selected frame provides central chilled water without the physical scale of the higher-capacity machines.

Defined water interfaces

DN300 evaporator and DN250 condenser connections support early plant piping coordination.

Efficient central-plant duty

Centrifugal compression is suited to steady medium facility loads with cooling-tower heat rejection.

พารามิเตอร์ทางเทคนิค

Cooling Capacity1055 kW
Input Power150.8 kW
Evaporator Flow45.36 l/s
Dimensions4533 x 2469 x 2852 mm
CompressorCentrifugal
Evaporator ConnectionDN300
Condenser ConnectionDN250
Heat RejectionWater-cooled condenser circuit
ControlIntegrated chiller capacity control
การปรับแต่งWater temperatures, electrical selection and plant interfaces can be configured for the intended application and operating environment.

Applications

Medium pharmaceutical buildings, healthcare facilities, electronics plants and clean manufacturing central chilled-water systems.

Solutions for Your Application

The plant needs centrifugal efficiency but cannot accommodate the longest high-capacity frame.Use the 4533 mm-long 1055 kW configuration and verify its service envelope against the plant room.
Piping pressure loss can rise if connection sizes are reduced late in design.Coordinate the DN300 evaporator and DN250 condenser interfaces with the scheduled flow rates from the start.

ตัวเลือกที่มีอยู่

Electrical voltage, starter arrangement, water-box pressure rating, isolation, flow sensing, communication and heat-exchanger accessories can be selected.

Planning a Water-Cooled Centrifugal Chiller 1055 kW specification?

ส่งมิติของคุณเงื่อนไขการติดตั้งเป้าหมายประสิทธิภาพและผิวที่ต้องการ

พูดคุยกับทีมงานของเรา
อีเมลถึงเรา WhatsApp WeChat

หน้าแรก

ผลิตภัณฑ์

ข่าวสาร

เกี่ยวกับเรา

ติดต่อเรา