ผู้จัดจําหน่ายแบบครบวงจรสําหรับอุปกรณ์ห้องคลีนรูมและสิ่งจําเป็นสําหรับสิ่งอํานวยความสะดวกปลอดเชื้อการสนับสนุนโครงการระหว่างประเทศ
Open mobile navigationClose mobile navigation
หน้าแรก / ผลิตภัณฑ์ / Containment & Biosafety Equipment / Sterility Test Isolator 4-Glove Negative-Pressure
STJH-STERILITY-TEST-ISOLATOR-4G-TOX

Sterility Test Isolator 4-Glove Negative-Pressure

A four-glove aseptic-toxic isolator using negative pressure and safe-change return filtration for potent-product sterility testing.
  • Negative-pressure aseptic-toxic mode
  • Four glove positions
  • Safe-change return filters
ขอใบเสนอราคา เรียกดูสินค้า

การแนะนําสินค้า

This variant combines Grade A or ISO 5 aseptic conditions with negative pressure for test articles that also require operator protection. Safe-change return filters distinguish the toxic configuration from the positive or neutral batch platform and provide a controlled maintenance interface for the contaminated air path.

คุณสมบัติที่สําคัญ

Dual protection objective

The pressure cascade contains potent sample hazards while filtered unidirectional air supports the test environment.

Protected filter servicing

Safe-change housings reduce direct exposure when a loaded return filter is replaced.

Integrated vapor cycle

Micro-nebulized hydrogen peroxide reaches the closed chamber before aeration and test release.

พารามิเตอร์ทางเทคนิค

Glove Ports4
Operating ModeAseptic-toxic
PressureNegative relative to the surrounding room
Work-Zone ClassificationEU Grade A / ISO 5
Supply FiltrationDouble HEPA configuration
Return FiltrationHEPA with safe-change housing
DecontaminationH2O2 micro-nebulization
Test MethodsMembrane filtration or direct inoculation
MonitoringParticles, microbiological parameters and process data option
การปรับแต่งPressure setpoint, filter housing, transfer system, glove layout and test hardware can be configured for the potent sample process.

Applications

Sterility testing of cytotoxic medicines, antibody-drug conjugates and highly active products requiring both aseptic conditions and personnel protection.

Solutions for Your Application

A positive-pressure sterility isolator could drive potent material outward after a breach.Use the negative-pressure aseptic-toxic mode to maintain inward leakage direction.
Changing a contaminated return filter presents a maintenance exposure point.Specify the safe-change housing and follow the contained filter-replacement procedure.

ตัวเลือกที่มีอยู่

Safe-change filter stages, pressure monitoring, transfer hatch, sterility-test equipment and environmental instruments can be configured.

Planning a Sterility Test Isolator 4-Glove Negative-Pressure specification?

ส่งมิติของคุณเงื่อนไขการติดตั้งเป้าหมายประสิทธิภาพและผิวที่ต้องการ

พูดคุยกับทีมงานของเรา
อีเมลถึงเรา WhatsApp WeChat

หน้าแรก

ผลิตภัณฑ์

ข่าวสาร

เกี่ยวกับเรา

ติดต่อเรา