Routine release tests consume replacement glass.
The flexible element can be reset with its key after operation.
This indoor release places a flexible operating element inside a square wall housing. Pressing the element changes the contact state, while a dedicated key restores the mechanism for reuse. Its double-pole changeover arrangement provides separate switching paths for door release and monitoring. Flush installation keeps the face close to the wall; a surface back box offers an alternative where the cable route is already exposed.
| Contact Arrangement | Double-pole changeover (DPCO) |
|---|---|
| Operating Element | Flexible resettable element |
| Reset Method | Dedicated reset key |
| Contact Rating | 3 A at 125–250 V AC |
| Flush Dimensions | 87 × 87 × 23 mm |
| Surface Dimensions | 87 × 87 × 58 mm |
| Ingress Protection | IP24 |
| Operating Temperature | -20 to +65 °C |
| Housing Color | Green |
| การปรับแต่ง | Mounting format and circuit connections can be adapted to the intended indoor application. |
The flexible element can be reset with its key after operation.
The surface back box accommodates installation without a flush recess.