A 643-ton double-cell tower using 40 hp fan power and 169240 CFM while retaining the 17 ft 3 in x 18 ft 1 in footprint.
  • 643 nominal tons
  • 40 hp fan power
  • Same plan footprint as lower model
ขอใบเสนอราคา เรียกดูสินค้า

การแนะนําสินค้า

This medium variant retains the lower tower's footprint and 9 ft 10 in height but raises fan power to 40 hp and airflow to 169240 CFM. The resulting 643-ton rating serves plants that need more heat rejection without expanding the plan area.

คุณสมบัติที่สําคัญ

Higher output per footprint

Increased fan and thermal hardware adds nominal tonnage without widening the two-cell frame.

Staged double-cell operation

The two air paths can respond independently to changing condenser load and service needs.

Increased induced airflow

The 169240 CFM fan duty draws more ambient air through the counterflow fill.

พารามิเตอร์ทางเทคนิค

Nominal Tonnage643 tons
Cell Quantity2
Fan Motor Selection40 hp class
Fan Airflow169240 CFM
Dimensions17 ft 3 in x 18 ft 1 in x 9 ft 10 in
Thermal ArrangementInduced-draft counterflow
BasinShared or divided collection arrangement by selection
Fan ControlVariable-speed or staged
InstallationOutdoor structural base
การปรับแต่งWater distribution, material and control options can be configured for the intended application and operating environment.

Applications

Medium-to-large clean manufacturing condenser-water systems, process chillers and pharmaceutical central utility plants.

Solutions for Your Application

The site cannot enlarge the tower footprint but needs more heat rejection than 585 tons.Use the 643-ton fan and thermal configuration within the same published plan dimensions.
Higher fan power can increase sound and electrical demand.Coordinate 40 hp supply, variable-speed control and acoustic treatment against the site limit.

ตัวเลือกที่มีอยู่

Low-sound fans, VFD control, basin heat, upgraded materials, drift eliminators, access ladders and water-treatment interfaces are available.