ผู้จัดจําหน่ายแบบครบวงจรสําหรับอุปกรณ์ห้องคลีนรูมและสิ่งจําเป็นสําหรับสิ่งอํานวยความสะดวกปลอดเชื้อการสนับสนุนโครงการระหว่างประเทศ
Open mobile navigationClose mobile navigation
STJH-DEDICATED-OUTDOOR-AIR-SYSTEM-2595CFM

Dedicated Outdoor Air System 2595 CFM

A compact 3-8 ton dedicated outdoor-air system supplying 350-2595 CFM for small clean and controlled spaces.
  • 350-2595 CFM supply range
  • 3-8 ton cooling class
  • Compact outdoor cabinet
ขอใบเสนอราคา เรียกดูสินค้า

การแนะนําสินค้า

The smallest selected DOAS cabinet combines outdoor-air cooling, dehumidification and supply-fan functions over a 350-2595 CFM range. Its compact refrigeration envelope serves clinics, laboratories and controlled workspaces whose ventilation load does not justify the larger multi-compressor platforms.

คุณสมบัติที่สําคัญ

Small-zone latent control

Dedicated refrigeration removes outdoor-air moisture before ventilation air enters the controlled room.

Matched compact capacity

The 3-8 ton range avoids applying a large central DOAS to a small ventilation load.

Packaged outdoor-air path

Filters, cooling circuit, fan and optional heat are integrated in one cabinet for a defined ventilation stream.

พารามิเตอร์ทางเทคนิค

Supply Airflow350-2595 CFM without energy recovery
Cooling Capacity3-8 tons
Electric Heat Range5-30 kW option
Cabinet ClassSmall packaged outdoor unit
RefrigerationDirect-expansion circuit sized to capacity
Supply FanVariable-speed option
FiltrationOutdoor-air filter section as selected
Humidity ControlCooling and reheat sequence options
InstallationOutdoor roof or slab mounting
การปรับแต่งHeat, filtration and control sequence can be configured for the intended application and operating environment.

Applications

Small laboratories, clinics, clean support rooms and controlled workspaces requiring independent outdoor-air cooling and dehumidification.

Solutions for Your Application

Ventilation air introduces more moisture than the room terminal equipment can remove.Use the dedicated cooling and optional reheat sequence to treat latent load before air reaches the space.
A large DOAS would cycle or operate outside an efficient range on a small zone.Select the compact 3-8 ton cabinet around the scheduled 350-2595 CFM ventilation demand.

ตัวเลือกที่มีอยู่

Electric heat, reheat, variable-speed fan, enhanced filtration, low-ambient accessories, sensors and building-control interfaces can be selected.

Planning a Dedicated Outdoor Air System 2595 CFM specification?

ส่งมิติของคุณเงื่อนไขการติดตั้งเป้าหมายประสิทธิภาพและผิวที่ต้องการ

พูดคุยกับทีมงานของเรา
อีเมลถึงเรา WhatsApp WeChat

หน้าแรก

ผลิตภัณฑ์

ข่าวสาร

เกี่ยวกับเรา

ติดต่อเรา