ผู้จัดจําหน่ายแบบครบวงจรสําหรับอุปกรณ์ห้องคลีนรูมและสิ่งจําเป็นสําหรับสิ่งอํานวยความสะดวกปลอดเชื้อการสนับสนุนโครงการระหว่างประเทศ
Open mobile navigationClose mobile navigation
STJH-CYTOTOXIC-DRUG-SAFETY-CABINET-900

Cytotoxic Drug Safety Cabinet 900 mm

A compact cytotoxic Class II cabinet using staged filtration in a 900 mm work-width format for low-volume hazardous-drug preparation.
  • 900 mm nominal work width
  • Staged HEPA filtration
  • Compact oncology footprint
ขอใบเสนอราคา เรียกดูสินค้า

การแนะนําสินค้า

This narrow configuration brings the serial-filter cytotoxic airflow architecture to pharmacies where frontage is limited. The stainless work interior is sized for one active preparation and essential supplies rather than the multiple-batch layouts accommodated by the wider models.

คุณสมบัติที่สําคัญ

Space-efficient containment

The 0.9 m format reserves less pharmacy frontage while maintaining a dedicated hazardous-drug work zone.

Serial filter path

Supply and staged exhaust filtration address the particulate burden associated with cytotoxic preparation.

Cleanable work interior

Stainless working surfaces support frequent wipe-down between small compounding runs.

พารามิเตอร์ทางเทคนิค

Nominal Work Width900 mm
Cabinet TypeCytotoxic Class II safety cabinet
Work-Zone Air QualityMinimum ISO 5 class
Supply FiltrationHEPA-filtered downflow
Exhaust FiltrationStaged serial HEPA arrangement
Interior MaterialStainless steel
Airflow MonitoringInflow and downflow monitoring
Work SurfaceRemovable or segmented cleanable trays
Primary DutyLow-volume cytotoxic preparation
การปรับแต่งService fixtures, base, exhaust connection and work-surface arrangement can be configured for the pharmacy workflow.

Applications

Small hospital oncology pharmacies, clinical-trial dose preparation and low-volume antineoplastic compounding in a suitable controlled room.

Solutions for Your Application

A standard wide cabinet will not fit the available oncology preparation bay.Use the 900 mm platform for one controlled preparation while keeping staging outside the active grille area.
Powder or aerosol residue can collect beneath a fixed work deck.Select removable tray sections that expose the collection area during the prescribed cleaning routine.

ตัวเลือกที่มีอยู่

Exhaust interface, service taps, electrical outlets, support base and segmented worktop configuration may be selected.

Planning a Cytotoxic Drug Safety Cabinet 900 mm specification?