ผู้จัดจําหน่ายแบบครบวงจรสําหรับอุปกรณ์ห้องคลีนรูมและสิ่งจําเป็นสําหรับสิ่งอํานวยความสะดวกปลอดเชื้อการสนับสนุนโครงการระหว่างประเทศ
Open mobile navigationClose mobile navigation
STJH-CYTOTOXIC-DRUG-SAFETY-CABINET-1200

Cytotoxic Drug Safety Cabinet 1200 mm

A 1200 mm cytotoxic cabinet balancing routine oncology batch capacity with a manageable pharmacy-room footprint.
  • 1200 mm work class
  • Removable stainless trays
  • Routine oncology throughput
ขอใบเสนอราคา เรียกดูสินค้า

การแนะนําสินค้า

The mid-width cabinet provides enough surface to separate supply, active compounding and waste positions during routine antineoplastic preparation. Removable stainless tray sections improve access for cleaning, while the serial filtration arrangement distinguishes it from a general-purpose Type A2 cabinet.

คุณสมบัติที่สําคัญ

Three-zone work layout

The 1.2 m surface can divide incoming items, active preparation and closed finished doses.

Accessible spill area

Segmented trays can be removed to reach surfaces below the primary work deck.

Airflow status oversight

Independent inflow and downflow monitoring helps operators recognize a change in the protective airflow state.

พารามิเตอร์ทางเทคนิค

Nominal Work Width1200 มม
Cabinet ConfigurationRecirculating cytotoxic Class II
Air QualityISO 5-class work zone
Filtration ArchitectureHEPA supply with serial exhaust filtration
Airflow MonitoringIndependent inflow and downflow channels
InteriorStainless steel
WorktopSegmented removable trays
SashMotorized front access option
Primary WorkloadRoutine antineoplastic compounding
การปรับแต่งTray layout, service locations, exhaust interface and support height can be adapted to the compounding sequence.

Applications

Daily oncology dose preparation, hazardous sterile compounding and pharmacy workflows that require distinct staging and waste positions.

Solutions for Your Application

Incoming supplies and waste encroach on the active compounding position.Allocate separate left, center and right zones across the 1200 mm work surface.
Routine surface wiping misses material beneath the work trays.Remove tray sections according to the cleaning procedure to expose the lower collection surfaces.

ตัวเลือกที่มีอยู่

Motorized sash, utility services, adjustable stand, exhaust connection and alternative stainless worktop layouts can be configured.

Planning a Cytotoxic Drug Safety Cabinet 1200 mm specification?

ส่งมิติของคุณเงื่อนไขการติดตั้งเป้าหมายประสิทธิภาพและผิวที่ต้องการ

พูดคุยกับทีมงานของเรา