Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Inicio / Productos / Cleanroom HVAC Systems / Steam Heating Coil One-Row 1-Inch
STJH-STEAM-HEATING-COIL-1ROW-1IN

Steam Heating Coil One-Row 1-Inch

A one-row steam coil with large 1 inch OD tubes for low air resistance, reliable condensate drainage and outdoor-air preheat.
  • One-row core
  • 1 inch OD tubes
  • Drainage-focused steam geometry
Solicite un presupuesto. Browse productos

Introducción del producto

The large-bore one-row coil prioritizes steam distribution and condensate drainage over a deep heat-transfer face. One-inch tubes and a single-row core suit outdoor-air preheat applications where low resistance and freeze resilience are important.

Características clave

Large condensate path

The one-inch tube bore supports gravity drainage and reduces sensitivity to trapped condensate.

Low air-side depth

A single row minimizes coil pressure loss in high outdoor-air volume systems.

Steam circuit choice

Distributing or non-distributing circuit arrangements can be selected around inlet air and freeze conditions.

Parámetros técnicos

Rows1
Tube Outside Diameter1 in
CircuitDistributing or non-distributing
CasingGalvanized or stainless steel
Fin MaterialAluminum or copper option
Heating MediumSteam
ConnectionsSteam supply and condensate return
Air-Side DutyLow-resistance outdoor-air preheat
InstallationPitched for positive condensate drainage
CustomizationFace size, circuit and materials can be configured for the intended application and operating environment.

Applications

Outdoor-air preheat, clean AHU freeze-protection sections, make-up air systems and low-resistance steam heating.

Solutions for Your Application

Condensate retained in a steam coil can cause water hammer or freeze damage.Use the large-bore one-row geometry and install the coil and trap for continuous positive drainage.
A deep coil adds excessive fan pressure to a high-volume outdoor-air path.Use the single-row core and select face area for acceptable air velocity.

Opciones disponibles

Distributing circuit, stainless casing, copper fins, face and connection orientation, intermediate drain and protective coating can be selected.

Planning a Steam Heating Coil One-Row 1-Inch specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo