STJH-SCROLL-COMPRESSOR-CHILLER-82KW

Air-Cooled Scroll Chiller 82 kW

The largest selected compact scroll chiller, providing 82.3 kW from a 25-ton-class chassis with a 24.5 kW compressor.
  • 82.3 kW cooling capacity
  • 24.5 kW compressor input
  • 25-ton compact chiller class
Solicite un presupuesto. Browse productos

Introducción del producto

This 25-ton-class model raises published cooling to 82.3 kW and uses a 24.5 kW compressor with a larger condenser surface. It serves higher-load clean utilities that still favor compact air-cooled scroll equipment over a screw or water-cooled plant.

Características clave

Largest compact scroll duty

The 82.3 kW output reaches the top of the selected scroll range for higher local process loads.

Expanded condenser surface

Additional coil area rejects the larger compressor heat load at outdoor conditions.

Central-plant alternative

The packaged air-cooled unit can serve a substantial local loop without tower-water infrastructure.

Parámetros técnicos

Cooling Capacity82.3 kW
Nominal Size25-ton class
Compressor Power24.5 kW
Condenser Fan Power2.8 kW
Compressor TypeScroll
Condenser SurfaceExpanded air-cooled coil
Water ControlLeaving-water setpoint control
Hydronic InterfaceExternal or integrated pump option
InstallationOutdoor packaged arrangement
CustomizationWater setpoint, low-ambient package and hydronic accessories can be configured for the intended application and operating environment.

Applications

Higher-load clean utility loops, electronics process cooling, pharmaceutical production support and controlled storage systems.

Solutions for Your Application

A 66 kW unit has too little margin for the verified peak process load.Use the 82.3 kW selection while confirming minimum-load operation and water volume.
The larger condenser can recirculate hot discharge air in a confined yard.Provide clear intake and vertical discharge space based on the final equipment arrangement.

Opciones disponibles

Integrated hydronics, buffer tank, low-ambient kit, coil coating, sound attenuation, power options and remote controls can be selected.

Planning a Air-Cooled Scroll Chiller 82 kW specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo
E-mail Nos WhatsApp WeChat

Inicio

Productos

Noticias

Nosotros

Contacto