Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Inicio / Productos / Equipos de sala limpia / High-Containment Weighing Booth 4 ft Double-HEPA
STJH-HIGH-CONTAINMENT-WEIGHING-4FT-DOUBLE-HEPA

High-Containment Weighing Booth 4 ft Double-HEPA

A four-foot recirculating enclosure using two HEPA filters in series and bag-in/bag-out filter handling.
  • Double HEPA filters in series
  • Bag-in/bag-out filter service
  • Four-foot compounding work zone
Solicite un presupuesto. Browse productos

Introducción del producto

This four-foot system adds redundant final filtration by placing two HEPA filters in series. Both filters can be independently scanned, and bag-in/bag-out service reduces direct contact with contaminated filters. The wider work area supports non-sterile hazardous-drug or potent-powder compounding that needs more staging space than the compact single-filter unit.

Características clave

Redundant filtration

Two series filters provide a second capture stage before air returns to the room.

Independent filter scanning

Each HEPA stage can be checked separately to support system verification.

Contained filter removal

BIBO hardware reduces exposure during replacement of loaded filters.

Parámetros técnicos

Nominal Width4 ft
Pressure ModeNegative work zone
Filter StagesTwo HEPA filters in series
Filter TestingIndependent scan access
Filter ChangeBag-in/bag-out
BlowerIntegrated recirculating system
Exhaust ModeRoom return after double filtration
Airflow MonitorAnalog
AplicaciónNon-sterile hazardous-drug and potent-powder work
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Applications

For non-sterile hazardous-drug and potent-powder compounding where double HEPA room recirculation is accepted by the facility's containment assessment. Procedures must cover BIBO filter changes.

Solutions for Your Application

A single HEPA stage does not provide the desired filtration redundancy.Use two independently scannable filters in series.
Removing a contaminated filter exposes maintenance staff.Use the bag-in/bag-out system and the site's controlled change procedure.

Opciones disponibles

Configure sash, work surface, airflow monitoring, electrical supply and BIBO accessories. Compound assessment determines whether recirculation is appropriate.

Planning a High-Containment Weighing Booth 4 ft Double-HEPA specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo
E-mail Nos WhatsApp WeChat

Inicio

Productos

Noticias

Nosotros

Contacto