Ваш универсальный поставщик оборудования для чистых помещений и асептических средствПоддержка международных проектов
Open mobile navigationClose mobile navigation
Главная / Продукция / Cleanroom HVAC Systems / Induced-Draft Counterflow Cooling Tower 585-Ton Double-Cell
STJH-INDUCED-DRAFT-COOLING-TOWER-585TON

Induced-Draft Counterflow Cooling Tower 585-Ton Double-Cell

A 585-ton double-cell induced-draft counterflow tower with 30 hp fan power and a 17 ft 3 in x 18 ft 1 in footprint.
  • 585 nominal tons
  • 30 hp fan-motor class
  • 154820 CFM tower airflow
Запрос котировки Просмотреть продукты

Введение продукции

This smallest selected double-cell frame provides 585 nominal tons in a 9 ft 10 in-high structure. Its 30 hp fan system moves 154820 CFM through two counterflow cells for medium chilled-water plants requiring serviceable evaporative heat rejection.

Основные характеристики

Two-cell operating flexibility

Separate cells allow staged fan operation and provide maintenance options within the plant strategy.

Counterflow thermal path

Air rises against falling water to concentrate heat transfer within a compact footprint.

Medium plant capacity

The 585-ton frame matches condenser-water loads that do not require the taller high-output variant.

Технические параметры

Nominal Tonnage585 tons
Cell Quantity2
Fan Motor Selection30 hp class
Fan Airflow154820 CFM
Dimensions17 ft 3 in x 18 ft 1 in x 9 ft 10 in
Flow ArrangementInduced-draft counterflow
Heat-Rejection MediumEvaporative condenser water
Fan ControlStaged or variable-speed option
InstallationOutdoor structural support
CustomizationMaterials, fan control and basin accessories can be configured for the intended application and operating environment.

Applications

Medium clean manufacturing chiller plants, pharmaceutical condenser-water systems and process-cooling installations.

Solutions for Your Application

The plant needs service flexibility without one large single-cell heat-rejection path.Use the double-cell arrangement and sequence cells around load and maintenance requirements.
Evaporative equipment can introduce drift and water-quality issues near clean facilities.Select suitable eliminators, water treatment and tower placement away from outdoor-air intakes.

Доступные варианты

Basin heater, variable-speed fans, enhanced drift eliminators, corrosion-resistant materials, access platforms, vibration controls and water-level package are selectable.

Planning a Induced-Draft Counterflow Cooling Tower 585-Ton Double-Cell specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.

Поговорите с нашей командой
Электронная почта WhatsApp WeChat

Главная

Продукция

Новости

О нас

Контакты