Pembekal Satu Henti Anda untuk Peralatan Bilik Bersih dan Kemudahan AseptikSokongan Projek Antarabangsa
Open mobile navigationClose mobile navigation
Laman Utama / Produk / Cleanroom HVAC Systems / Induced-Draft Counterflow Cooling Tower 585-Ton Double-Cell
STJH-INDUCED-DRAFT-COOLING-TOWER-585TON

Induced-Draft Counterflow Cooling Tower 585-Ton Double-Cell

A 585-ton double-cell induced-draft counterflow tower with 30 hp fan power and a 17 ft 3 in x 18 ft 1 in footprint.
  • 585 nominal tons
  • 30 hp fan-motor class
  • 154820 CFM tower airflow
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

This smallest selected double-cell frame provides 585 nominal tons in a 9 ft 10 in-high structure. Its 30 hp fan system moves 154820 CFM through two counterflow cells for medium chilled-water plants requiring serviceable evaporative heat rejection.

Ciri-ciri Utama

Two-cell operating flexibility

Separate cells allow staged fan operation and provide maintenance options within the plant strategy.

Counterflow thermal path

Air rises against falling water to concentrate heat transfer within a compact footprint.

Medium plant capacity

The 585-ton frame matches condenser-water loads that do not require the taller high-output variant.

Parameter teknikal

Nominal Tonnage585 tons
Cell Quantity2
Fan Motor Selection30 hp class
Fan Airflow154820 CFM
Dimensions17 ft 3 in x 18 ft 1 in x 9 ft 10 in
Flow ArrangementInduced-draft counterflow
Heat-Rejection MediumEvaporative condenser water
Fan ControlStaged or variable-speed option
InstallationOutdoor structural support
PenyesuaianMaterials, fan control and basin accessories can be configured for the intended application and operating environment.

Applications

Medium clean manufacturing chiller plants, pharmaceutical condenser-water systems and process-cooling installations.

Solutions for Your Application

The plant needs service flexibility without one large single-cell heat-rejection path.Use the double-cell arrangement and sequence cells around load and maintenance requirements.
Evaporative equipment can introduce drift and water-quality issues near clean facilities.Select suitable eliminators, water treatment and tower placement away from outdoor-air intakes.

Pilihan yang boleh didapati

Basin heater, variable-speed fans, enhanced drift eliminators, corrosion-resistant materials, access platforms, vibration controls and water-level package are selectable.

Planning a Induced-Draft Counterflow Cooling Tower 585-Ton Double-Cell specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat

Laman Utama

Produk

Berita

Tentang Kami

Hubungi Kami