Главная / Продукция / Containment & Biosafety Equipment / Closed Restricted Access Barrier System 6 ft ISO 4 Negative-Pressure Hazardous-Compounding
STJH-CLOSED-RABS-6FT-ISO4-CHEMO

Closed Restricted Access Barrier System 6 ft ISO 4 Negative-Pressure Hazardous-Compounding

A six-foot hazardous-compounding closed RABS providing a longer negative-pressure deck for separated sterile process stages.
  • 6 ft intermediate length
  • One or two transfer chambers
  • Separated process staging
Запрос котировки Просмотреть продукты

Введение продукции

The intermediate chassis adds two feet of working length over the compact version without the room demand of the eight-foot system. It can be arranged with one or two transfer chambers, allowing purchasers to balance directional material flow against wall space and daily batch volume.

Основные характеристики

Balanced work capacity

The six-foot deck gives routine batches room for measuring, active mixing and final-container handling.

Selectable transfer architecture

One interchange saves space, while two can establish separate supply and waste or product routes.

Condition alarms

Differential-pressure indication and an audible alarm make loss of the intended operating state visible to users.

Технические параметры

Standard Length6 ft
Depth2.5 ft
Height6.75 ft
Main ChamberNegative pressure, ISO Class 4, vertical unidirectional airflow
Transfer ChambersOne or two, ISO Class 5 at static and dynamic conditions
Transfer-Chamber Length12 in each
AirflowAt least 400 cfm; at least 40 fpm at 6 in from filter face
FiltrationHEPA, nominal 99.99% DOP at 0.3 µm, with bag-out
ControlsDifferential-pressure gauges, audible alarm and mechanical door interlock
CustomizationTransfer count, glove layout, worktop fittings, exhaust arrangement and support height can be matched to the intended compounding sequence.

Applications

Routine hazardous sterile compounding, oncology dose batches and pharmacy workflows that need distinct supply, mixing and finishing positions inside one barrier.

Solutions for Your Application

The four-foot model is too crowded, but an eight-foot unit exceeds the available room.Use the six-foot chassis as the intermediate capacity and footprint option.
The pharmacy is unsure whether one or two transfer chambers are necessary.Map inbound supplies and outbound product or waste, then select a shared or directional two-airlock arrangement.

Доступные варианты

Single or dual transfer chambers, glove-port quantity, secondary HEPA, lift stand, shelving, IV bar, outlets and disposal ports can be configured.

Planning a Closed Restricted Access Barrier System 6 ft ISO 4 Negative-Pressure Hazardous-Compounding specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.

Поговорите с нашей командой
Электронная почта WhatsApp WeChat

Главная

Продукция

Новости

О нас

Контакты