Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Início / Produtos / Equipamento de Cleanroom / Negative-Pressure HEPA Filtration Unit 16 × 36 in
STJH-NEGATIVE-PRESSURE-HEPA-UNIT-16X36

Negative-Pressure HEPA Filtration Unit 16 × 36 in

An intermediate-length narrow reverse-flow unit for controlled exhaust across a 36 in collection face.
  • 15.7 x 35.63 in footprint
  • 48 lb product weight
  • 120 V variable-speed exhaust
Solicite um orçamento. Browse produtos

Introdução do produto

This model extends the narrow reverse-flow cabinet to 35.63 in while retaining a 15.7 in width and 16.125 in height. The additional filter length serves wider maintenance and isolation zones without moving to the 48 in chassis. A room-side dust pan, MERV 7 prefilter and 120 V variable-speed PSC blower define its service and control arrangement.

Características-chave

Intermediate capture length

The 36 in body covers more ceiling area than the compact model while remaining easier to place than the longest unit.

Accessible filter change

Room-side access keeps the maintenance path within the controlled enclosure.

Stable narrow geometry

A 48 lb powder-coated steel cabinet balances extended filter area with manageable suspended weight.

Parâmetros técnicos

Product Dimensions15.7 W x 35.63 D x 16.125 H in
Product Weight48 lb
Flow ModeDuctless reverse-flow exhaust
HEPA Performance99.99% at 0.3 µm
Coarse StageMERV 7 prefilter
Fan Assembly1/4 hp PSC backward-curved blower
Power Input120 V, 0.9 A, 105 W, single phase, 50/60 Hz
Speed ControlVariable
Service SideRoom-side with dust collector pan
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Applications

Appropriate for medium isolation rooms, powder-maintenance enclosures and controlled construction bays requiring a longer negative-pressure pickup. Ceiling support should account for the 48 lb unit before filter loading.

Solutions for Your Application

The short 24 in unit leaves part of the work zone outside the exhaust pickup.Use the 36 in filter length to extend capture along the enclosure ceiling.
Overhead access is obstructed by utilities.Plan filter replacement from the room side and preserve clear access to the collector pan.

Opções disponíveis

Specify frame adapter, duct connection, suspension eyes, pressure alarm and local or grouped controls. Confirm structural support and replacement-air route.

Planning a Negative-Pressure HEPA Filtration Unit 16 × 36 in specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Fale com a nossa equipe
Email-nos O WhatsApp WeChat

Início

Produtos

Notícias

Sobre nós

Contato