Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Início / Produtos / Cleanroom HVAC Systems / Hot-Water Heating Coil Two-Row 3/8-Inch
STJH-HOT-WATER-HEATING-COIL-2ROW-38IN

Hot-Water Heating Coil Two-Row 3/8-Inch

A shallow small-tube coil for low-load reheat branches where water volume and casing depth must remain low.
  • Two-row shallow core
  • 3/8 in compact tubing
  • Low water volume
Solicite um orçamento. Browse produtos

Introdução do produto

This two-row coil uses 3/8 in outside-diameter tubes on a compact pattern with corrugated aluminum fins. It is the shallowest and lowest-water-volume option in this heating-coil group, making it suitable for small terminal or AHU reheat sections. The light core reduces spatial demand, but face size, entering-water temperature and circuit count must still be selected from the actual cleanroom sensible load.

Características-chave

Minimal casing depth

Two tube rows reduce the space required in a compact reheat section.

Responsive water circuit

Small tubes and low contained water volume support quick output changes under modulating control.

Standard finned construction

Corrugated aluminum fins increase surface area within a galvanized clean-air casing.

Parâmetros técnicos

Tube Rows2
Tube Outside Diameter3/8 in
Tube MaterialCopper by standard clean-water selection
Fin MaterialCorrugated aluminum
CasingGalvanized steel
Coil DepthShallow two-row construction
FluidClosed-loop hot water
CircuitingSelected for flow and pressure drop
Primary DutyLow-load heating or reheat
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Applications

For small cleanroom reheat terminals, compact AHUs and low-temperature hot-water branches with modest sensible heating loads.

Solutions for Your Application

The shallow coil cannot deliver the required winter output at low water temperature.Rate the actual face size, airflow and entering-water temperature; select more rows when the two-row core lacks surface area.
Small tubes create excessive water pressure drop in a poorly circuited coil.Choose circuit quantity and connection size from the design flow rather than forcing all water through one long path.

Opções disponíveis

Confirm coil face, airflow, water temperatures, circuit count, connection side, fin spacing, casing finish and freeze protection.

Planning a Hot-Water Heating Coil Two-Row 3/8-Inch specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Fale com a nossa equipe
Email-nos O WhatsApp WeChat

Início

Produtos

Notícias

Sobre nós

Contato