A DN50 medium-head inline pump using a 1.1 kW motor and longer 200-class hydraulic for controlled-production chilled water.
  • DN50 flanged inline body
  • 1.1 kW motor
  • 200 hydraulic head class
Solicite um orçamento. Browse produtos

Introdução do produto

The 1.1 kW version retains DN50 flanges but uses a longer impeller and 200 head-class hydraulic. It suits medium AHU coil circuits whose pipe, valve and heat-exchanger resistance exceeds the range of the compact 0.75 kW pump.

Características-chave

Higher branch pressure

The extended hydraulic overcomes a medium network resistance without increasing pipe connection size.

Electronic speed option

Variable-speed control can follow valve position or differential pressure as coil demand changes.

Serviceable inline layout

The motor and cartridge remain accessible above the pipe centerline in a planned service zone.

Parâmetros técnicos

Flange SizeDN50
Motor Power1.1 kW
Hydraulic Head Class200
Maximum Working Pressure16 bar
Pump ConstructionInline centrifugal
ImpellerExtended medium-head hydraulic
ControlVariable-speed differential-pressure option
FluidClosed-loop chilled water
MountingInline pipework with independent support
CustomizaçãoFlow setpoint, sensor package and valve accessories can be configured for the intended application and operating environment.

Applications

Medium chilled-water circulation for controlled-production AHUs, clean packaging coils and laboratory distribution branches.

Solutions for Your Application

The lower-head pump cannot overcome the combined valve and coil pressure drop.Use the 200-class hydraulic after plotting the required operating point on the pump curve.
Constant-speed operation may create excess differential pressure as valves close.Use electronic speed control with a suitably located pressure sensor.

Opções disponíveis

Integrated drive, remote pressure sensor, isolation and balancing valves, non-return valve, insulation and building-control connection can be selected.