Your One-Stop Supplier for Cleanroom Equipment and Aseptic Facility EssentialsInternational Project Support
Open mobile navigationClose mobile navigation
Home / Products / Cleanroom Doors, Windows & Interlocks / Slim Cleanroom Access Control Card Reader 125 kHz Mullion
zhengfeng-SLIM-CLEANROOM-ACCESS-CONTROL-CARD-READER-125KHZ

Slim Cleanroom Access Control Card Reader 125 kHz Mullion

A narrow reader for retaining a defined legacy proximity-card population, with controller format and installed read performance checked together.
  • Legacy Credential Format Matching
  • Narrow Mullion Installation
  • Controller-Driven Access Decisions
Request a Quote Browse Products

Keeping a defined legacy credential system in service

This 125 kHz mullion reader is intended for a door where existing proximity cards or fobs must remain usable and the frame offers little mounting width. It reads a compatible credential and sends data to an external access controller. The controller applies access rights, time schedules and any airlock permissions; the reader does not independently authorize entry or operate an interlock sequence.

The important replacement detail is the complete credential format. Two cards using 125 kHz can use different encoding or data layouts. Record the installed reader interface, representative card types, bit length and controller interpretation of facility and card numbers before ordering. A reader beep establishes presentation feedback; it does not prove that the panel accepted the number or that the lock released.

Interface and mounting references

Selection itemBasis for the door schedule
Credential band125 kHz; supported card family and encoding must match the existing population
Body envelope152 × 43 × 25.4 mm nominal reference; use the supplied mounting drawing for holes and cable entry
Power5–16 V DC preliminary reference; confirm the selected hardware rating and peak demand
Controller outputWiegand or clock-and-data configuration, selected for the panel input
Local feedbackLED and beeper functions coordinated with panel wiring and settings

These numerical references describe the proposed format, not a test certificate or an interchangeable replacement guarantee. Wiegand and clock-and-data are different signalling arrangements; matching wire colours is insufficient. Spare conductors may be needed for host-controlled indications. The reader supply, data reference and shield treatment must follow the actual reader and panel instructions.

Installation on a cleanroom door frame

Check both the 43 mm face width and clearance for opening the cover or removing the reader. A narrow housing can still obstruct a seal retainer or glazing bead. Provide a protected cable exit and a sealed wall penetration compatible with the cleanroom partition. Potting protects the electronic assembly but does not establish a washdown rating for the casing, cable joint or completed installation.

Trial the actual cards on the finished frame before drilling a series of doors. Metal backing, nearby readers and card presentation orientation can change installed performance. Measure voltage at the reader during operation, particularly when the same supply also serves locks; a supply disturbance can resemble an intermittent card fault.

Handover and maintenance

Acceptance should demonstrate valid and invalid credentials, correct event numbers in the controller, denied-access feedback and recovery after a power interruption. Keep a tested spare configuration and record the wiring assignment. Clean the face with an approved wipe method and inspect cable strain relief rather than spraying into joints. Where encrypted reader communication or a new smart-card programme is required, select a suitable reader and controller together instead of treating this legacy interface as a security upgrade.

Planning your Slim Cleanroom Access Control Card Reader 125 kHz Mullion specification?

Send us your dimensions, installation conditions, performance targets and required surface finish.

Talk to Our Team