Single MgO Rock Wool Cleanroom Panel 75 mm Handcrafted
- Metal end closures protect cut core edges.
- A single board supports the selected process face.
A custom wall module with one defined backed face
This 75 mm handcrafted panel encloses a rock-wool section and a single MgO board within coated steel faces and galvanized perimeter members. Individually fabricated modules allow the wall layout to accommodate custom heights, widths and prepared openings while preserving a defined edge connection.
Place the reinforcement where the design needs it
The one-sided board arrangement needs an explicit orientation mark. A process-side designation can help installers, but the selected face should follow the actual equipment interface, loading and required evidence. The opposite surface still needs the coating and cleaning resistance appropriate to its room exposure.
Reference effective widths are 980 or 1180 mm, with 0.4–0.8 mm steel faces and a rock-wool density selection of 100–120 kg/m³. The 75 mm depth includes all layers. Panel lengths must suit the supported wall height and delivery route; a fabrication maximum would not establish a free-standing height or lifting method.
Make custom openings into complete details
Place service penetrations and equipment apertures on the module drawing before manufacture. Their edges need closure to protect the core, but loads from a door, pass box or equipment bracket require a separate reinforcement decision. Cutting away the perimeter frame on site can change both the load path and the ability to seal the connection.
Coordinate the panel edge with adjacent modules, floor track, ceiling junction and corner trims. Sealant selection must suit both surfaces and the cleaning regime. A visually flush cover strip may still conceal an unsealed opening into the core.
Compare quotations by construction
State which face contains the board, actual metal thickness, board type, coating and joint geometry. Include custom openings, internal reinforcement, perimeter components and installation rather than comparing only a price per square metre. Where fire or acoustic performance is required, use evidence for the asymmetric assembly and its tested orientation.
Acceptance should verify labels, orientation, opening geometry, frame condition and bond records. Review moisture movement and metal compatibility for the supplied MgO material. During maintenance, inspect frequently cleaned junctions and disturbed service openings. Repair must restore both the room surface and the enclosed layers; a new trim alone cannot remedy a weakened bond or wet core.
Planning your Single MgO Rock Wool Cleanroom Panel 75 mm Handcrafted specification?
Send us your dimensions, installation conditions, performance targets and required surface finish.