Single-Leaf Cleanroom Swing Door Bi-Flush
- Both room faces receive the same flush treatment.
- Aligned surfaces reduce frame ledges at the entrance.
- A single leaf retains conventional hinged operation.
Aligned faces on both sides of the partition
The bi-flush single door is arranged so the closed leaf and frame present aligned surfaces on both approaches. A powder-coated aluminum hollow-profile frame supports a bonded metal-faced leaf with aluminum-honeycomb or rock-wool infill. This suits adjoining controlled rooms where both wall faces need an easily wiped transition.
Achieving both planes makes coordination with the finished wall thickness especially important. A frame can be square and operate correctly while still projecting on one side if the wall or facing build differs from the ordered section. Establish the actual finish-to-finish thickness, including liners, before final fabrication.
Build and finish schedule
| Component | Listed reference |
|---|---|
| Operation | Single-action hinged leaf. |
| Alignment | Leaf and frame flush on both sides, coordinated with the partition planes. |
| Frame | Powder-coated aluminum hollow-chamber profile. |
| Leaf | Metal faces bonded around aluminum honeycomb or rock wool. |
| Installation fittings | Listed EV1 anodized aluminum fittings; color/finish appearance to be confirmed against the frame finish. |
| Optional floor seal | Lowering bottom seal with a defined floor and removal detail. |
Powder coating and anodizing are different finishes and need not look identical. Approve visible finish interfaces where they meet. Core choice, facing grade and hardware reinforcement affect the completed assembly; bi-flush geometry does not establish fire resistance, sound insulation or a particular leakage value.
Preserving alignment during installation
Provide support at hardware fixing zones and avoid distorting the hollow frame while tightening anchors. Check both faces for alignment and the full swing for clearance. Hardware may still project from an otherwise flush leaf; handle and closer positions must be shown if they affect cleaning or adjacent equipment.
The wall-frame joint needs a continuous maintainable seal. Where a drop seal is selected, ensure it retracts without scraping and can be replaced without disturbing the whole leaf. Do not reduce necessary operating gaps simply to produce a more flush appearance.
Handover and maintenance
Quote both-side frame details, selected core and finish, hardware, bottom seal if needed, partition preparation and fitting. Acceptance should measure clear passage and both surface planes, inspect perimeter joints and verify closing with the room ventilation active. Maintenance should check changes in gaps, gasket contact and finish damage on both sides; new misalignment may indicate jamb movement or hinge wear. Keep the installation drawing with the door schedule for later wall or hardware changes.