Home / Products / Air Ducts & Air Distribution / Single-Duct VAV Reheat Terminal Unit DN300 High-Capacity Hot-Water
zhengfeng-SINGLE-DUCT-VAV-REHEAT-TERMINAL-DN300-HW-HC

Single-Duct VAV Reheat Terminal Unit DN300 High-Capacity Hot-Water

size the expanded coil for actual water conditions, airflow range, pressure losses and zone requirements.
  • Expanded coil selected for actual water and air conditions
  • Broad inlet retains variable airflow control for larger zones.
Request a Quote Browse Products

An expanded reheat section for a larger controlled zone

The DN300 hydronic VAV terminal combines a larger inlet with an expanded downstream hot-water coil section. A larger active coil face can change velocity and provide room for a different heat-transfer arrangement, but the High-Capacity name is not a heating rating. Select the coil against the actual airflow and water conditions.

Low-temperature water needs a complete selection

Lower entering-water temperature reduces the available temperature difference between water and air. Recovering the required heating output may call for a different face area, number of rows, circuiting or water flow. Those changes also affect air and water pressure losses. Simply specifying an oversized casing or larger pipe does not establish the result.

The 3/4 in piping reference needs a defined connection convention and joint type on the selected drawing. Nominal pipe size and copper-tube outside diameter are different descriptions. Confirm connection handing and leave room for the control valve, isolation and coil removal without imposing pipe loads on the terminal.

Coordinate air control across the operating range

ConditionRequired decision
Maximum coolingInlet, coil and downstream pressure losses with sound at the selected flow.
Minimum ventilationReliable sensor range and the room or process minimum.
HeatingAirflow and water-valve sequence with a suitable discharge temperature.
Reduced central pressureResponse when the terminal can no longer maintain the airflow target.

Multipoint pressure sensing supports a closed control loop; it does not remove inlet-flow-profile requirements. Avoid sizing the inlet so large that the required minimum flow falls below the reliable measurement range. A terminal serving several rooms also controls their combined flow, not every branch independently.

Specify the package and service route

The reference assembly has a galvanized casing and rectangular discharge, with optional acoustic treatment. A downstream attenuator adds length and resistance that belong in the complete selection. Provide access to controls, sensing tubes, coil faces and water connections.

Quote selected heating duty with entering and leaving conditions, water pressure drop, airflow range, controller, valve package and all accessories. Handover should demonstrate both airflow limits, heating response and required room-pressure coordination. Inspect probe condition, damper motion, coil cleanliness and hydraulic connections in service. Reheat changes temperature but does not independently remove moisture.

Planning your Single-Duct VAV Reheat Terminal Unit DN300 High-Capacity Hot-Water specification?

Send us your dimensions, installation conditions, performance targets and required surface finish.