Rectangular Duct Silencer 600 x 300 x 1000 mm
- The wider acoustic section suits medium ventilation branches.
- A constant body length simplifies allocation within a straight duct run.
A medium attenuator with a fixed one-metre body
The 600 x 300 x 1000 mm silencer provides a welded galvanized enclosure for internal absorbing elements in a supply or return branch. Its larger duct interface can suit a medium air quantity while fitting a defined straight length. The internal passages, rather than gross inlet dimensions alone, determine the velocity through the acoustic section.
Hold length fixed without fixing the acoustic design
Within a one-metre body, absorber thickness, number, spacing and facing can change the frequency response and flow resistance. A wider inlet does not prove the pressure drop is low. Selection must compare insertion loss by frequency band, regenerated noise and total pressure loss at the design and reduced flows.
| Item | Catalog reference |
|---|---|
| Connection | 600 x 300 mm nominal. |
| Length | 1000 mm body. |
| Casing | Welded galvanized sheet steel. |
| Media | Internal absorbing arrangement selected for the application. |
| Flange | 640 x 340 mm reference envelope with 9 mm holes; complete drilling pattern by approval drawing. |
Supply and return installations can present different source sound and flow direction. Obtain data for the relevant orientation and operating condition. ISO 7235 laboratory measurements distinguish attenuation, flow noise and pressure loss; a single acoustic number leaves those tradeoffs unresolved.
Installation effects and cleaning access
A nearby elbow or a poorly aligned transition can load passages unevenly and change the pressure and noise result. Reserve the required approach and discharge geometry along with the one-metre casing. Do not consume all available duct length with the silencer before checking those interfaces.
Specify media containment and cleanability for the actual supply or return stream. A protective film or facing may change acoustic performance; a hygienic construction should be selected with its own data rather than added over exposed absorber material on site. Keep the unit dry and inspect for damaged facings or deposited material.
Procurement and acceptance
The price scope should identify absorber arrangement, facing, shell, flanges, supports and any inspection provisions. State required octave-band attenuation, acceptable self-noise and pressure budget at a defined air quantity. A physically interchangeable casing may contain a different acoustic construction.
Handover should confirm the supplied internal design, airflow direction, support and joint sealing, followed by the agreed airflow/pressure and sound checks. Investigate bypass paths or other downstream noise sources if room performance differs from the prediction. A silencer cannot correct structural vibration or noise that enters beyond its location.