Your One-Stop Supplier for Cleanroom Equipment and Aseptic Facility EssentialsInternational Project Support
Open mobile navigationClose mobile navigation
Home / Products / Air Ducts & Air Distribution / Rectangular Duct Silencer 600 x 300 x 1000 mm
zhengfeng-RECTANGULAR-DUCT-SILENCER-600X300X1000

Rectangular Duct Silencer 600 x 300 x 1000 mm

A medium one-metre absorber casing provides a defined envelope while its internal arrangement determines airflow resistance and frequency-dependent attenuation.
  • The wider acoustic section suits medium ventilation branches.
  • A constant body length simplifies allocation within a straight duct run.
Request a Quote Browse Products

A medium attenuator with a fixed one-metre body

The 600 x 300 x 1000 mm silencer provides a welded galvanized enclosure for internal absorbing elements in a supply or return branch. Its larger duct interface can suit a medium air quantity while fitting a defined straight length. The internal passages, rather than gross inlet dimensions alone, determine the velocity through the acoustic section.

Hold length fixed without fixing the acoustic design

Within a one-metre body, absorber thickness, number, spacing and facing can change the frequency response and flow resistance. A wider inlet does not prove the pressure drop is low. Selection must compare insertion loss by frequency band, regenerated noise and total pressure loss at the design and reduced flows.

ItemCatalog reference
Connection600 x 300 mm nominal.
Length1000 mm body.
CasingWelded galvanized sheet steel.
MediaInternal absorbing arrangement selected for the application.
Flange640 x 340 mm reference envelope with 9 mm holes; complete drilling pattern by approval drawing.

Supply and return installations can present different source sound and flow direction. Obtain data for the relevant orientation and operating condition. ISO 7235 laboratory measurements distinguish attenuation, flow noise and pressure loss; a single acoustic number leaves those tradeoffs unresolved.

Installation effects and cleaning access

A nearby elbow or a poorly aligned transition can load passages unevenly and change the pressure and noise result. Reserve the required approach and discharge geometry along with the one-metre casing. Do not consume all available duct length with the silencer before checking those interfaces.

Specify media containment and cleanability for the actual supply or return stream. A protective film or facing may change acoustic performance; a hygienic construction should be selected with its own data rather than added over exposed absorber material on site. Keep the unit dry and inspect for damaged facings or deposited material.

Procurement and acceptance

The price scope should identify absorber arrangement, facing, shell, flanges, supports and any inspection provisions. State required octave-band attenuation, acceptable self-noise and pressure budget at a defined air quantity. A physically interchangeable casing may contain a different acoustic construction.

Handover should confirm the supplied internal design, airflow direction, support and joint sealing, followed by the agreed airflow/pressure and sound checks. Investigate bypass paths or other downstream noise sources if room performance differs from the prediction. A silencer cannot correct structural vibration or noise that enters beyond its location.

Planning your Rectangular Duct Silencer 600 x 300 x 1000 mm specification?

Send us your dimensions, installation conditions, performance targets and required surface finish.

Talk to Our Team
Inquiry Form

Home

Products

News

About Us

Contact Us