Rectangular Duct Silencer 400 x 200 x 1000 mm
- The shallow airway fits low-height branch duct routes.
- Flanged ends provide a removable connection for duct servicing.
Acoustic treatment within a shallow branch
The rectangular silencer places sound-absorbing elements inside a nominal 400 x 200 mm duct section with a 1000 mm body. It is intended to reduce duct-borne sound approaching an occupied room or leaving a small fan while retaining a low-height connection format.
Absorbing surfaces dissipate part of the sound energy as air passes through their passages. They also occupy space in the flow path. Matching the duct connection does not guarantee unchanged free area or negligible pressure loss.
Geometry and acoustic selection
| Item | Catalog reference |
|---|---|
| Nominal connection | 400 x 200 mm. |
| Body length | 1000 mm. |
| Shell | Welded galvanized sheet steel. |
| Internal treatment | Sound-absorbing media with arrangement selected for the duty. |
| End flange | 440 x 240 mm reference envelope, 9 mm fixing holes; hole centres and profile by drawing. |
Choose using octave-band source sound and the required downstream limit. One overall dB reduction cannot describe performance at every frequency. Insertion loss, flow-generated sound and total pressure loss should be evaluated together for the actual airflow and passage arrangement. ISO 7235 provides a relevant laboratory test basis; it does not itself certify this product.
A shallow airway leaves limited room for obstructions
Increasing absorber thickness or reducing passage spacing may alter attenuation while increasing air velocity and resistance. Check regenerated noise as well as the fan-pressure allowance. A one-metre installation constraint may require a different acoustic layout when low-frequency treatment dominates.
Coordinate fan outlets, bends and transitions so the inlet condition is consistent with the selection data. Support the silencer independently as required and leave room for flange fasteners and removal. External flange size is not a complete drilling specification.
Media protection and acceptance
Select the absorber facing for the air stream and cleaning regime, including fibre containment, moisture and cleaning access where relevant. Do not assume loose exposed media are acceptable because the connected room is called a cleanroom. Inspect damaged facings, deposits and wet areas during maintenance.
Quote the exact baffle/media arrangement, facing, airflow, pressure allowance, octave-band data, flange and support scope. Acceptance should verify the construction and installation, measured airflow/pressure and agreed acoustic result at defined operating conditions. A laboratory insertion-loss value will not automatically equal the change in room sound level.
Planning your Rectangular Duct Silencer 400 x 200 x 1000 mm specification?
Send us your dimensions, installation conditions, performance targets and required surface finish.