Polyurethane Cleanroom Sandwich Panel 75 mm Four-Side Framed PUR
- Perimeter members enclose the insulation ends.
- Individual modules accommodate component layouts.
Framed PUR modules around windows and services
The 75 mm four-side framed panel is intended for insulated partitions interrupted by glazing, doors or planned service interfaces. A perimeter frame encloses the foam and metal skins of each module, allowing the wall to be arranged around these components. The benefit comes from coordinating the complete opening before manufacture rather than assuming every cut piece behaves like a continuous panel.
The frame closes the edge and creates a thermal detail
Metal perimeter members can carry heat around the insulation. A room with a temperature difference therefore needs an assessment of frames, connectors and glazing returns as well as the foam centre. Local surface temperatures may govern condensation risk at a window even when the broad wall area is adequately insulated. Glazing, gaskets and seals should form a continuous boundary with the selected panel system.
The reference construction is 75 mm overall, with 980 or 1180 mm effective widths, 0.4–0.8 mm steel faces and 0.6–0.8 mm frame metal. These choices affect mass and connection geometry. Frame thickness alone does not establish a capacity to carry glazing or a door: section shape, corner connections, fixings and the route to the supporting structure are also relevant. Hand assembly describes manufacture, not a guaranteed structural or insulation performance.
Prepare the opening as part of the wall
Set out the glazing sightline, clear opening, frame overlap and service access on one drawing. Separate the opening required by equipment from the larger framed construction opening. A factory preparation can enclose the core and incorporate reinforcement, while an unplanned site cut can interrupt both the bond and the perimeter load path.
Heavy pipework, cabinets and door closers need their own designed support. Align modules without forcing twisted frames together, then complete the specified seals. During use, inspect the lower corners of glazing and penetrations for condensation or seal movement. Recurring moisture requires assessment of the thermal detail and room conditions, not just another bead of sealant.
Agree a complete module schedule
Quotation should identify panel sizes, face finish, frame sections, opening reinforcement, glazing responsibilities, connectors and sealing work. Require declared thermal data for the proposed PUR build and assembly-specific evidence for any fire or loading requirement. Acceptance should check dimensions and squareness, concealed reinforcement records, glazing support and continuous perimeter seals against the coordinated drawings.
Planning your Polyurethane Cleanroom Sandwich Panel 75 mm Four-Side Framed PUR specification?
Send us your dimensions, installation conditions, performance targets and required surface finish.