PIR Insulated Cleanroom Panel 50 mm with 1000 mm Cover Width
- Meter-wide cover supports straightforward panel scheduling.
- Thin foam section limits partition footprint.
A one-metre layout module for compact insulated walls
The 50 mm PIR panel uses pre-painted galvanized steel on both sides of a rigid polyisocyanurate core. Its 1000 mm effective cover width provides a repeatable module for compact laboratory and cleanroom partitions. The thin wall section can preserve useful floor area when the thermal calculation and required interfaces permit it.
Set out the room from effective coverage
Effective cover is the distance added by an installed panel after its joint is engaged. It is not necessarily the overall sheet width. Start the layout from doors, glazing and fixed equipment so that the last bay does not become a narrow strip that is difficult to support or seal. Corner profiles and end connections need their own dimensional allowances.
The reference face-gauge range is 0.5–0.8 mm. Thicker steel can change local dent behaviour and handling weight, but it does not substitute for reinforcement at mounted equipment. Select the paint system for the room cleaning method and specify both faces when exposure differs across the wall.
A compact section still needs a complete enclosure design
Choose 50 mm from temperatures, humidity, heat-load objectives and declared thermal data for the actual panel. PIR chemistry alone does not assign a U-value, maximum service temperature or fire classification. A shallow insulated partition is not automatically a freezer enclosure, and increasing foam performance does not close an unsealed joint.
Base profiles locate the panel and form part of the connection. L-bar corner trims finish the change in direction. Their structural anchorage, air sealing and thermal functions must be shown separately in the detail. Avoid treating a visible trim as proof that the concealed core and seal are continuous. Recessed electrical boxes may consume much of a 50 mm section, so plan their backing and edge closure before cutting.
Installation and purchasing checks
Keep joints aligned and use the specified seals without forcing distorted panels into place. Inspect the base and corners for gaps, damaged paint and recurring condensation. Repairs should restore the joint construction, not merely hide an exposed foam edge.
Compare quotations using the same effective coverage, cut-panel schedule, face gauges, coatings, tracks, trims, reinforced openings and installation scope. Acceptance should verify the module dimensions, approved thermal and fire documentation where required, support details and continuous room boundaries. A regular one-metre grid simplifies scheduling only when its end conditions are included.
Planning your PIR Insulated Cleanroom Panel 50 mm with 1000 mm Cover Width specification?
Send us your dimensions, installation conditions, performance targets and required surface finish.