zhengfeng-PERFORATED-STEEL-RAISED-ACCESS-FLOOR-AF38

Perforated Steel Raised Access Floor 38% Open-Area Heavy-Duty Ventilation

A welded tubular frame and selected perforated face are matched to a complete support arrangement.
  • Up to 38% free cross-section
  • Welded tubular steel structure
  • Selectable reinforcement and flow regulation
Request a Quote Browse Products

Reinforced ventilation selected as one assembly

This steel panel family combines a powder-coated welded tubular frame with a perforated face on a nominal 600 mm grid. The reference family offers 30–38 mm depths and patterns up to 38% free cross-section. Select an exact pattern, frame and reinforcement arrangement rather than treating the largest opening and highest possible load as one universal specification.

The steel beneath the perforations carries load to the pedestals or other supports. Increasing openings removes material from the face; reinforcement must therefore be assessed with the hole layout. The heavy-duty designation requires evidence for the complete supplied configuration.

Balance point loads and air pressure

Equipment feet, rolling wheels and distributed loads are different cases. Establish their positions and contact areas, plus the allowable deflection, before selecting the panel. A generic 3–5 kN family range does not qualify every pattern or support arrangement and is not a repeated rolling-load rating.

Air delivery depends on differential pressure, the selected perforations and any covering or regulator. A flow rate without its pressure condition is incomplete. Use the panel curve with the final plenum layout and account for service trays and equipment that can obstruct the path.

Regulation and installation access

An optional underside regulator changes local resistance. Provide a safe way to reach it for commissioning and subsequent adjustment without removing supports beneath loaded equipment. The regulator requires clear travel space below the panel.

Coordinate finished level, seating and compatible supports with adjacent floor modules. Planned cut-outs need their own reinforcement and edge details. Choose a coating or facing that suits cleaning and any electrical requirement while preserving the specified openings.

Handover and service

Mark panel positions and regulator settings in the floor schedule. After rack or service changes, inspect the air path and rebalance affected zones. Remove debris from openings, inspect frame welds and coating damage, and correct rocking through the intended supports.

The quotation should identify each load/pattern variant, regulator, finish, understructure and commissioning scope. Acceptance requires the selected load evidence, dimensional fit and airflow at the installed pressure. A representative panel should remain removable for planned service access.

Planning your Perforated Steel Raised Access Floor 38% Open-Area Heavy-Duty Ventilation specification?

Send us your dimensions, installation conditions, performance targets and required surface finish.