Perforated Steel Raised Access Floor 25% Open-Area
- 25% round-hole open area
- Welded tubular steel frame
- Optional top-adjustable airflow damper
Round-hole air delivery on a supported floor grid
This reference 600 × 600 mm steel ventilation module has a perforated top welded to a tubular frame, with a nominal 35 mm overall depth and a 25% opening pattern. The powder-coated face provides a distributed air path at selected technical-room positions. Its support must match a 600 mm modular floor system; the module dimension must not be confused with stringer section depth.
An optional top-adjustable damper allows local flow regulation without lifting the panel. Keep its adjustment point reachable after racks or equipment are installed. A damper regulates available air; it cannot overcome inadequate plenum pressure or a blocked route beneath the floor.
Geometry, flow and loading need separate checks
The nominal 25% open area is a geometric specification. Use the selected panel and damper pressure-flow curve to establish delivery at the operating pressure. Include any perforated covering in that assessment, because a facing can reduce the effective opening or add resistance.
This configuration is not selected for repeated rolling traffic. Route heavy trolleys over suitable solid or separately rated modules. Sharing a grid with cement-filled panels does not transfer their load capacity to the ventilating face. Stationary loads and pedestrian use also need the specified panel and support evidence.
Fit and maintain the air path
Check seating width, panel depth and finished elevation against adjacent modules. Similar plan dimensions alone do not establish interchangeability. Protect the damper during installation and ensure its movement is not obstructed by cables or supports.
Record panel positions and settings during balancing. Clear dust from openings and inspect the coating, welds and frame seating when a panel is removed. Return it to the correct location and recheck flow after equipment or underfloor services change.
Quotation and acceptance
Define the panel drawing, finish, compatible understructure, damper and permitted traffic in the order. Quote balancing, transitions and any local supports separately from panel supply. Acceptance should verify the opening pattern, fit, damper access and operation, load documentation and measured airflow at the commissioned pressure. Keep transport routes distinct from the selected ventilation positions.
Planning your Perforated Steel Raised Access Floor 25% Open-Area specification?
Send us your dimensions, installation conditions, performance targets and required surface finish.