Perforated Face Air Diffuser 623 mm with DN315 Connection
- DN315 interface provides a broad air-entry route.
- Large face aligns with the wider modular ceiling format.
A broad inlet behind a larger ceiling face
The 623 x 623 mm perforated diffuser contains a fixed radial swirl assembly with a nominal DN315 connection. It offers a larger entry path for a mixed-air supply branch while retaining a concealed blade arrangement. The panel is intended for the corresponding wider ceiling format; it should not be forced into a 600 mm nominal grid.
Keep the room duty separate from the panel size
A large inlet can reduce neck velocity for a given airflow, but the total pressure and sound depend on the diffuser, inlet conditions and damper position. The label higher-volume does not define a rated capacity. Selection needs the tested curve for the supplied assembly and the required flow at both maximum and minimum operating conditions.
Swirling discharge mixes supply with room air. Where a large branch serves a room containing high partitions or equipment, a single high-flow outlet may leave uneven conditions. Compare its tested throw and spacing with a layout using several smaller terminals. A broad face is not proof of uniform process protection.
Build and connection schedule
| Item | Reference arrangement |
|---|---|
| Outside face | 623 x 623 mm perforated galvanized sheet steel. |
| Nominal connection | DN315; verify actual spigot fit and sealing method. |
| Coatings | RAL 9010 face and RAL 9005 internal element. |
| Blades | Fixed radial geometry for horizontal swirl. |
| Optional box | Horizontal entry, with acoustic lining if specified. |
A side-entry box requires space for its width, inlet bend and suspension. Do not compress a flexible branch against a structural beam merely to fit the box; the resulting uneven inlet may undermine the selection data. The larger duct and box need support that does not rely on the perforated panel.
Maintain the hidden air path
Provide enough access to inspect the swirl insert and plenum as well as the white face. Acoustic lining should have a surface and attachment suitable for the cleaning regime, with no assumption that an acoustic option is a cleanroom qualification. Face perforations must remain open and the blades undamaged.
Include the selected box, lining, balancing device, ceiling frame, supports and any external insulation in the price scope. Define acceptance for airflow, regenerated sound, accessible adjustments and distribution in the occupied zone. Sound power in a terminal data sheet and sound pressure measured in a room are different quantities; use a consistent basis when comparing a specified noise limit with the supplier's evidence.
Planning your Perforated Face Air Diffuser 623 mm with DN315 Connection specification?
Send us your dimensions, installation conditions, performance targets and required surface finish.