Home / Products / Air Ducts & Air Distribution / Perforated Face Air Diffuser 598 mm with DN200 Connection
zhengfeng-PERFORATED-FACE-AIR-DIFFUSER-598-DN200

Perforated Face Air Diffuser 598 mm with DN200 Connection

A nearly flush perforated face hides the fixed radial swirl element, with a DN200 inlet and ceiling retention selected as a complete assembly.
  • Medium collar supports a larger branch than DN125.
  • Concealed internal vanes preserve an even perforated face.
Request a Quote Browse Products

A concealed outlet for a nearly flush ceiling

The 598 x 598 mm perforated face hides fixed radial blades supplied through a DN200 connection. This arrangement is intended for mixed-air comfort supply in controlled-area support rooms. The face provides a consistent visible surface while the internal swirl element defines the discharge pattern.

A concealed-grid appearance is an installation choice, not a universal fit. The face edge, overlap, retention and removal clearance must agree with the ceiling system. A panel that looks flush but cannot be removed without disturbing adjacent tiles is a maintenance problem, especially where the space above the ceiling has restricted access.

Catalog configuration

ComponentReference specification
Face598 x 598 mm perforated galvanized steel.
InletDN200 nominal; actual joint dimensions on the assembly drawing.
Visible finishRAL 9010 white; alternative RAL finish by selection.
Internal elementFixed radial steel blades, RAL 9005 black.
ConnectionVertical collar or plenum arrangement; optional lined box.
Air patternHorizontal swirling supply.

What the larger inlet does and does not change

Compared with a smaller diameter at the same volume flow, a larger inlet reduces average neck velocity. The complete terminal still has losses through the swirl element, perforated face and any damper. Its capacity cannot be inferred from the inlet area alone. Evaluate the actual combination at design and reduced flow for sound, pressure loss and throw.

The swirl entrains surrounding air to reduce temperature and velocity differences as the supply moves through the room. This makes the unit appropriate for a mixing objective, but unsuitable as evidence of a protected unidirectional zone. Locate the outlet relative to walls, returns and tall obstructions; aesthetic alignment alone is insufficient.

Access and purchasing detail

Support the box independently as required by its mounting design. Keep the joint sealed and leave access to the balancing device. A lined box needs a documented cleanable surface and an appropriate cleaning method for the application; coating colour does not establish hygiene performance.

Schedule the face removal method, grid detail, connection orientation, lining, damper, insulation and suspension in the quotation. During cleaning, inspect the hidden blades and restore the face without distortion. Handover should include the measured airflow and damper setting, checks for loose parts and unwanted noise, and any agreed occupied-zone measurements. Do not use gross perforated-panel area as an unverified airflow factor.

Planning your Perforated Face Air Diffuser 598 mm with DN200 Connection specification?

Send us your dimensions, installation conditions, performance targets and required surface finish.

Talk to Our Team