Your One-Stop Supplier for Cleanroom Equipment and Aseptic Facility EssentialsInternational Project Support
Open mobile navigationClose mobile navigation
Home / Products / Air Ducts & Air Distribution / Motorized Volume Control Damper 1800 x 1170 mm Opposed-Blade 40 Nm
zhengfeng-MOTORIZED-VOLUME-CONTROL-DAMPER-1800X1170-40NM

Motorized Volume Control Damper 1800 x 1170 mm Opposed-Blade 40 Nm

A wide opposed-blade bank requires a coordinated structural and drive arrangement for central ventilation control.
  • Coordinated Drive and Linkage for a Wide Blade Bank
  • Wide landscape frame suits central ventilation routes.
Request a Quote Browse Products

Control a wide central ventilation opening

This 1800 × 1170 mm opposed-blade damper uses an external drive arrangement with a nominal 40 Nm actuator for a central supply or return route. Its broad frame accommodates trunk-scale ductwork. The design must coordinate blade span, supporting structure and drive transmission so that the entire bank moves as intended.

Large dimensions require more than a larger motor

A 40 Nm label must be checked against the actual torque required by the complete blade bank. Pressure loads, seals and bearings set part of the torque demand, while shaft twist and linkage geometry affect how motion reaches the far end of a wide bank. Sectioning, intermediate support or a different drive arrangement may be required by the actual construction. These details belong on the assembly drawing.

ReferenceCoordination point
1800 × 1170 mm galvanized frameOpening and flange dimensions, lifting points, support stiffness and installed access.
Opposed blade motionBlade spans, sections, bearings and synchronization through the full travel.
40 Nm modulating driveModel-specific torque, duty, shaft connection, running time and environmental protection.
24 V AC/DC; 2–10 V optionsTransformer load, cable requirements, scaling and supervisory sequence.

Changing a trunk opening affects several downstream zones. Define whether the command comes from measured airflow, duct pressure or another system controller, and coordinate it with downstream regulating devices. A fixed position signal alone cannot maintain the desired total volume as system resistance changes.

Install and inspect the complete transmission path

Lift and support the frame using the approved points, without using blades or shafts as lifting members. Prevent the adjoining ducts from racking the casing. Leave access along the external linkage so the technician can observe more than the actuator end.

Commission by checking actual blade movement at both ends and through intermediate positions under the intended load. A feedback output may show normal actuator travel while a disconnected remote blade remains stationary. Investigate oscillation, unequal movement and rising friction before increasing motor size or adjusting stops.

Define the performance evidence

Quote the assembly with the drive, support/interface requirements, switches and selected bearings clearly identified. Require pressure-duty and torque evidence for the offered construction, plus agreed position, control and airflow tests. IP protection, tight shut-off and automatic safe positioning need separate model-specific documentation; they are not consequences of a 40 Nm rating.

Planning your Motorized Volume Control Damper 1800 x 1170 mm Opposed-Blade 40 Nm specification?

Send us your dimensions, installation conditions, performance targets and required surface finish.

Talk to Our Team