Motorized Volume Control Damper 1000 x 840 mm Opposed-Blade 20 Nm

A wider opposed-blade assembly needs documented drive selection and synchronized travel through its external linkage.
  • Drive Sized for the Actual Blade and Pressure Duty
  • Analogue modulation supports changing trunk airflow demand.
Request a Quote Browse Products

Modulate a wider branch with coordinated blades and drive

The 1000 × 840 mm galvanized damper uses opposed aerofoil blades operated through an external linkage by a nominal 20 Nm actuator. It can serve a larger supply or return branch when its position is commanded by the ventilation controls. Opposed action changes the opening progressively, but the relationship between angle and airflow remains dependent on the duct system.

Verify the load instead of relying on a nominal torque margin

A nominal 20 Nm motor requires a documented torque selection for this assembly. Blade span, seals, bearings, pressure direction and linkage friction all affect required torque. The drive must achieve the intended travel at the worst specified operating condition, including starting from a seated position. Request the damper manufacturer's torque basis and the actuator model before treating the combination as approved.

Reference arrangementProject requirement
1000 × 840 mm opposed blade bankFrame dimensions, blade action, pressure duty and support detail.
20 Nm nominal actuatorUsable torque, shaft and bracket interface, running time and duty cycle.
24 V AC/DC and 2–10 V optionsPower sizing, command/feedback mapping and required overrides.

Position feedback is a drive indication, not an independent flow sensor. An external flow or pressure controller must define the demand if that is the intended controlled quantity. Specify loss-of-power and loss-of-signal behaviour separately; neither follows from analogue modulation. Enclosure protection also belongs to the actual actuator and installed cable entry, rather than an assumed IP54 rating.

Preserve alignment across the blade bank

Provide supports that keep the frame rectangular and leave service space beside the external linkage. Duct joints must not squeeze the housing. Check all blades while cycling the drive, since a loose link can leave part of the bank incorrectly positioned despite a plausible feedback signal.

Inspect shaft clamps, bearings, seals and linkages during planned service. Persistent high operating effort calls for investigation of alignment or contamination; replacing the motor with a stronger one can damage the mechanism.

Quotation and handover

Include the complete damper-drive assembly, mounting parts, optional end indication and selected seals in the quotation. Supply operating pressure, airflow, required response and controls sequence. Acceptance should verify loaded travel, blade synchronization, feedback and specified overrides, with separate airflow and leakage tests where those performances are required.