Motorized Shut-Off Damper DN400 Class 4 24 V 10 Nm
- A high platform provides clearance around the larger casing.
- Torque Selection for the Actual Pressure Duty
A large sealed disc with a raised actuator platform
The DN400 configuration uses a single gasketed disc in a galvanized casing and a nominal 10 Nm, 24 V AC/DC on-off actuator. A raised platform provides a mounting offset around the larger cylindrical body. It must also hold the drive in the correct shaft alignment rather than simply lift it above the casing.
Nominal torque needs an application margin
Matching actuator output to a quoted minimum without a sizing allowance does not demonstrate adequate operation under the actual pressure, gasket friction and service conditions. Selection needs the damper's breakaway, running and seating requirements and the actuator manufacturer's sizing allowance. The available torque and any fail-safe return torque must be assessed for the chosen drive.
| Item | Reference configuration |
|---|---|
| Nominal bore | DN400. |
| Body/disc | Galvanized casing and single circular shutoff blade. |
| Seal | EPDM perimeter gasket. |
| Actuator selection | 10 Nm nominal, 24 V AC/DC, on-off. |
| Mounting | Raised platform; exact height, shaft engagement and restraint by assembly drawing. |
| Options | Position indication and connection accessories. |
Class 4 is the requested closed-blade leakage class, subject to a report for this assembly, pressure and standard edition. It is separate from casing leakage or the airtightness of site-installed joints. Larger diameter does not automatically retain the performance of a smaller damper.
Mechanical and control interfaces
Support the duct and body without ovalizing the casing. Ensure the large disc clears screws and connections through its full stroke. The platform must remain accessible after insulation and ceiling work, and the actuator needs its required anti-rotation support. A taller platform is not evidence of a higher permissible temperature.
Define command wiring, power capacity, stroke time and failure position. Position contacts help verify motion but cannot confirm gasket leakage. If the process needs closure without power, select an appropriate fail-safe mechanism explicitly.
Maintenance and purchase scope
Inspect the long gasket perimeter, shaft coupling and platform rigidity when closure becomes noisy or incomplete. Use compatible EPDM replacements and the prescribed seating adjustment, then recheck operation and leakage as required. Quote the complete body, platform, actuator, feedback, connectors and test scope. Acceptance should establish adequate torque at the duty conditions, unobstructed travel and documented leakage, rather than relying on the nominal 10 Nm label alone.