Modular Cleanroom Wall Panel 60 mm Flush with Service Void
- The internal cable route keeps conduit away from the exposed wall surface.
- Variable-width modules accommodate narrow infill locations.
Route services inside a 60 mm wall without losing access
This modular wall concept places a longitudinal service passage within a 60 mm metal-faced panel. It suits instrument wiring where exposed conduit would obstruct cleaning. The nominal 25 mm passage describes a planning feature, not the usable size of every opening or permission to install any electrical service.
Cables must pass through the narrowest connector, entry and bend, not just the straight void. A plug can be larger than its cable, and the required bending radius can prevent an otherwise small cable from turning into a box. Prepare a route drawing that includes panel joints, door heads, equipment exits and accessible termination points before specifying modules.
The passage and insulation share limited space
A 60 mm overall section includes skins and internal components. The service route reduces or interrupts the insulation locally, so thermal performance needs the actual cross-section and core specification. The panel name does not identify a foam chemistry, mineral fill or fire rating. Concealed wiring also requires the applicable electrical design, cable separation and protective details; a void is not automatically an approved raceway.
| Selection | Required coordination |
|---|---|
| 60 mm panel and nominal 25 mm route | Show clear dimensions at joints, bends and boxes on the fabrication drawing. |
| Module widths and lengths | Fit the room grid, delivery route and service exits; agree available increments with the supplied system. |
| Polyester or laminated face options | Select the actual finish against cleaning agents and repair requirements. |
Install for safe maintenance
Protect cables from cut metal edges and avoid fixings that intrude into the passage. Close the route around entries so the cavity does not become an uncontrolled connection between rooms. Locate inspection points where cables can be replaced without dismantling an entire progressive wall; a larger accessible service module may be more practical than a narrow hidden route.
Quote wall modules, route components, protective entries, boxes, access covers and cable installation as defined items. Acceptance should check route continuity and usable clearance before closure, then inspect seals and record the as-built route. Electrical verification belongs to the installed service design. Keep those records for future drilling, cable replacement and cleaning of accessible covers.
Planning your Modular Cleanroom Wall Panel 60 mm Flush with Service Void specification?
Send us your dimensions, installation conditions, performance targets and required surface finish.