Magnesium Oxysulfate Cleanroom Panel 50 mm Hollow
- Internal channels support a planned service-routing arrangement.
- Thin section suits restricted partition footprints.
A shallow hollow-mineral wall with planned service routes
The 50 mm magnesium oxysulfate panel contains longitudinal cavities separated by mineral webs beneath its exterior faces. The hollow layout provides space for a coordinated wiring arrangement inside a compact partition, reducing the need for exposed conduit where the service design permits it.
Start with the cable and box layout
A hollow passage is not automatically an approved electrical raceway. The electrical design must establish whether a separate conduit is needed, how cables enter and leave the panel, and how connections remain accessible. In a shallow wall, the clear cavity and service-box depth can be much smaller than the 50 mm overall panel thickness. Map them before manufacturing.
Protect cable entries at metal cut edges and close the opening around the service component. Routing across a mineral web requires a designed detail rather than indiscriminate drilling. The webs support the faces, so removing them can affect local strength and leave a larger enclosed void open to the room.
Specify a complete panel family
Reference widths include 950, 980, 1150 and 1180 mm. These are alternative module formats to be coordinated with the selected edge system, not a set of automatically interchangeable pieces. State effective cover width, joint geometry, face material and coating on the schedule.
Magnesium oxysulfate identifies the binder family. Moisture stability, bond durability, thermal performance and fire behaviour require evidence for the actual formulation and assembled panel. A mineral description does not establish waterproof construction or permit exposed core edges in a wet-cleaning area.
Install and maintain the enclosed route
Set panel height from the wall supports and openings; fabrication length is not a structural span. Ceiling use needs a separate load and support specification. Seal joints, bases, heads and service entries to preserve the room boundary while keeping designated electrical access available.
For quotation, provide elevations, the service plan, module format, supported height and finish requirements. Include conduit provisions, boxes or closures, tracks and installation in the scope. Acceptance should verify cavity positions, dimensions, material identity, face and bond condition and complete service-edge closures. Keep an as-built route record so later fixings do not damage concealed cables or cut through supporting webs.
Planning your Magnesium Oxysulfate Cleanroom Panel 50 mm Hollow specification?
Send us your dimensions, installation conditions, performance targets and required surface finish.