Linear Slot Air Diffuser Two-Slot 20 x 1200 mm
- Two independent slots support split discharge patterns.
- Matched Plenum and Separate Slot Settings
Two independently directed air streams
This 1200 mm aluminum linear section contains two nominal 20 mm slots. Separate pattern controls allow opposite horizontal discharge, a common direction or a selected downward pattern. This is useful where one ceiling line serves two adjacent areas, but a common inlet does not make the two slots independently controlled air-volume zones.
Split direction does not guarantee equal flow
Blade position changes the path and resistance of each stream. Opposed settings can produce different flows if the inlet or controller positions are asymmetric. Compare the exact pattern with the relevant performance data and balance the assembly after setting the directions. A layout requiring separately scheduled or variable quantities on each side may need separate plenums or terminals.
| Parameter | Catalog reference |
|---|---|
| Slots | Two passages, 20 mm nominal width each. |
| Length | 1200 mm nominal section. |
| Construction | Extruded aluminum; optional white powder coat. |
| Controls | Independent manual pattern adjustment per slot. |
| Connection | Matched plenum option, insulated where selected. |
| Ends and runs | End caps or joined sections with alignment pieces. |
Coordinate the room and the continuous line
For a central ceiling line, opposing streams may serve both sides of the room. Near a wall, sending one stream into a short distance can produce a different room pattern from sending both inward. Specify room dimensions, ceiling height, flow per active length, supply temperature and nearby obstructions before choosing the controller settings.
Two 20 mm slots do not imply twice the capacity of a particular single-slot diffuser: its width, geometry, sound and pressure limits differ. Likewise, 1200 mm overall length may include end details that are not active discharge area. Show active, blank and joined sections separately on the drawing.
Access and evidence for handover
The plenum must distribute air along both slots without twisting the frame. Provide suspension and sealed inlet connections, and keep balancing devices accessible after ceiling completion. Insulation needs a continuous vapour-control detail at cold joints. Preserve blade positions during cleaning and avoid painting over the movable parts.
The quotation should list the two-slot face, border, end caps, joins, active length, insulated or plain plenum, inlet and volume control. Acceptance includes measured volume, recorded settings for each slot, secure assembly and distribution on both sides of the line. The adjustable direction is a commissioning feature, not an automatic room-balancing system.
Planning your Linear Slot Air Diffuser Two-Slot 20 x 1200 mm specification?
Send us your dimensions, installation conditions, performance targets and required surface finish.