Your One-Stop Supplier for Cleanroom Equipment and Aseptic Facility EssentialsInternational Project Support
Open mobile navigationClose mobile navigation
Home / Products / Air Ducts & Air Distribution / HVAC Damper Actuator 40 Nm 24 V High-Torque
zhengfeng-HVAC-DAMPER-ACTUATOR-40NM-FLOATING

HVAC Damper Actuator 40 Nm 24 V High-Torque

A high-torque rotary drive accepts directional floating commands for large dampers, with the full linkage and position-verification method coordinated.
  • The larger torque output suits mechanically demanding blade banks.
  • A manual release assists alignment during shaft installation.
Request a Quote Browse Products

A high-torque drive for a coordinated blade bank

The 40 Nm, 24 V rotary actuator is a non-fail-safe selection for large dampers or jackshaft-linked blade banks. Floating three-point control uses separate opening and closing commands; when neither command is active, the drive stops according to its control design. It does not inherently receive an absolute analog position target.

Control timing and actual position

A controller may estimate position from the accumulated drive time. That estimate can drift if travel is obstructed, power is interrupted or the mechanism is moved manually. Position feedback or an approved endpoint synchronization method is needed where actual position must be known. Interlock the directional commands as required by the wiring instructions.

The catalog's 150-second-per-90-degree timing is a selection target for the actual model and load, not a universal value for all 40 Nm drives. An on-off wiring option also requires a supported circuit; changing the control label alone does not make the interfaces interchangeable.

ItemReference selection
Output class40 Nm nominal.
Supply24 V AC/DC.
CommandFloating three-point, with supported on-off arrangement if selected.
Failure functionNon-fail-safe.
Mechanical accessExternal manual release, shaft clamp and mounting bracket.
OptionsJackshaft linkage, shaft extensions and mounting fittings.

Large torque requires a strong load path

Size the drive from breakaway, running and seating torque at the intended differential pressure. The jackshaft, couplings, linkage arms, brackets and blade attachments must carry the transmitted load. A high-torque motor can damage a weak linkage rather than cure a binding damper.

Keep shafts aligned and allow for the selected linkage geometry through the full travel. Added extensions may introduce deflection or lost motion. Avoid using a gross damper-area estimate as the sole sizing method, particularly with multiple sections or damaged seals.

Service and acceptance

Use the manual release only under the prescribed conditions and re-engage it before testing. Inspect clamps, anti-rotation restraint and linkage fasteners during maintenance. Define power-loss behaviour explicitly; a non-fail-safe drive does not promise a return to closed.

Request an exact model, timing, shaft range, electrical sizing, interface and accessories in the quotation. Acceptance should check both directions, stop behaviour, full-bank movement, endpoint alignment and any position feedback. Running/holding watt values and ambient limits must come from that model's data; nominal torque alone supplies none of them.

Planning your HVAC Damper Actuator 40 Nm 24 V High-Torque specification?

Send us your dimensions, installation conditions, performance targets and required surface finish.