High-Temperature Double-Wall Exhaust Duct DN600 Ceramic-Fibre 760 °C Continuous
- Large liner diameter suits combined industrial exhaust volume.
- Stainless outer skin encloses the ceramic thermal layer.
A large insulated riser requires an engineered load path
This DN600 double-wall exhaust section uses a broad stainless gas passage with an insulated outer jacket. The reference liner diameter is 24 inches, approximately 610 mm. It is a candidate for large process routes where both gas-flow design and the structural support of the complete riser are significant.
Flow area and shared-process duty
Determine the bore from combined exhaust flow, acceptable pressure loss and equipment backpressure limits. Connecting several sources requires assessment of their simultaneous operation, gas compatibility and potential interaction when one source is off. A large passage alone does not establish a balanced common exhaust system.
The 760 °C designation is a required service category that needs evidence for the supplied system, including its liner, insulation, joints and supports. The thermal capability of ceramic fibre does not establish the continuous rating of the complete duct. Record normal operation, cleaning cycles and temperature excursions together with pressure and condensate exposure.
Separate thermal movement from structural restraint
A tall hot liner grows as its temperature rises. A riser arrangement needs defined load-carrying supports, guides and provisions for expansion; anchoring every section can turn thermal growth into damaging forces. Offsets and connected equipment create additional load paths. Use actual assembly weights, including insulation, fittings and accessories, for support and lifting design.
Outdoor portions also need the relevant wind and environmental assessment. An overlapping outer jacket is only one weather detail: roof flashings, terminations and support penetrations must manage water without obstructing the intended movement. Keep the system-specific clearance space and penetration construction specified for the actual exhaust duty.
Plan delivery and future inspection
The outside diameter exceeds the 610 mm gas bore. Coordinate lifting access, section lengths, joint working space and the complete insulated envelope before ordering. Large components must be handled without distorting the liner ends or disturbing the thermal layer. Conical joints require the mating parts and engagement procedure of the selected system.
The quotation should identify the complete route, transitions, structural supports, expansion components, access, drains and termination. Acceptance should verify system identity and temperature evidence, material records, installed supports, joints, clearances and commissioning results. Provide accessible inspection points at deposit-prone locations and changes of direction. During maintenance, investigate corrosion, displaced joints or movement marks before replacing a section with a documented compatible component.
Planning your High-Temperature Double-Wall Exhaust Duct DN600 Ceramic-Fibre 760 °C Continuous specification?
Send us your dimensions, installation conditions, performance targets and required surface finish.