Flush-Mounted Cleanroom Utility Wall Panel 60 mm Magnetic-Face
- Magnetic retention avoids exposed hinges.
- Reinforced sheet face remains a separate removable component.
- Module aligns with a shallow partition run.
Shallow access without a projecting hinged door
The 60 mm utility module uses a reinforced removable metal face held against its frame by recessed magnets. It offers front access to concealed wiring or local service connections while the closed surface aligns with the surrounding wall. The separate face can be taken away, so there is no permanent door leaf in a narrow corridor.
The overall depth is not the usable service space. Reinforcement, magnets, back face and device boxes occupy part of the section. A shallow module should be laid out around the largest connector and the cable bend, including the space needed to disconnect it. If these cannot be reached without straining the cable, a larger accessible service zone is preferable.
Separate retention from sealing and electrical protection
| Component | Selection basis |
|---|---|
| 60 mm wall interface | Match the actual perimeter profile and finished face position. |
| Reinforced metal facings | Specify sheet gauge, stiffeners and handling weight for the supplied module. |
| Recessed magnets | Define holding arrangement, release method and any additional retention required. |
| Perimeter joint | Choose a repeatable seal suited to the room pressure and cleaning regime. |
Magnetic attraction holds the face in position; it does not establish an airtight joint, an electrical enclosure rating or protective bonding. Electrical services need their own compliant boxes and protection, and any required bonding of removable metal parts must remain effective after access.
Install for repeated removal
Support devices and cables from the fixed structure where practical. Avoid making the loose face carry connections that are pulled each time it is removed. Provide a clear place to lift and store the panel without damaging its edge or finish. Isolate relevant services before exposing the cavity.
Quote the frame, removable face, retention, seal, openings and separately specified service fittings. Acceptance should demonstrate removal and replacement, verify accessible terminations and check the closed face and seal. Maintenance includes cleaning debris from the seating surfaces, inspecting retention components and replacing damaged seals with the specified type.
Planning your Flush-Mounted Cleanroom Utility Wall Panel 60 mm Magnetic-Face specification?
Send us your dimensions, installation conditions, performance targets and required surface finish.