Fire-Rated Rock Wool Cleanroom Panel 75 mm Steel-Framed Fire-Resistant

The selected connector and perimeter details form part of the documented wall assembly.
  • Defined perimeter keeps the module boundary rigid.
  • Two connection routes suit different assembly systems.
Request a Quote Browse Products

A framed 75 mm mineral wall with a selected joint system

This panel combines rock-wool infill, metal faces and galvanized edge framing in a 75 mm section. Continuous edges and separate aluminum-profile connections are alternative assembly routes. For a fire-rated partition, the chosen route must be included in the applicable evidence and installation design.

A connector change can change the tested boundary

Panel joints affect how adjacent modules move, retain their edges and resist heat or flame passage during exposure. An aluminum profile and a continuous folded joint cannot be exchanged merely because they fit the same thickness. Seal material, joint geometry, fixings and supporting members all belong in the documented build.

Set the required fire-resistance criteria and duration for the project, then check the classification or accepted report against the actual construction. A mineral-wool reaction-to-fire result is not a time rating for the wall. Likewise, a cleanroom air-leakage requirement remains a separate criterion that the installed joints must address.

Use frame dimensions as inputs, not performance guarantees

Reference options are 980, 1160, 1180 or 1200 mm module widths and 0.5–1.0 mm faces. The perimeter uses reference 0.8 mm galvanized stock with 1.0 mm corner pieces. Agree the section geometry, corner fastening and protective finish. Supported height and pressure capacity depend on the full sandwich and connections, not simply the gauge of the corner metal.

Coordinate glazing and door openings with reinforcement and protected interfaces. A framed hole can be mechanically sound yet fail to maintain the required fire boundary. Service sleeves and movement joints need details appropriate to the specific opening and wall assembly.

Purchase and inspect the selected version

Quotation should name the connector version, panel build, performance classification, supports, opening schedule and installation responsibilities. Include any required joint or penetration protection rather than leaving it as an undefined site accessory. Manufacturing length is not evidence of an approved unsupported wall dimension.

During installation, inspect concealed frame and joint work before it is covered by trims. Acceptance should compare materials, fixings and perimeter conditions with the approved record. In service, investigate loose connections, corrosion, impact damage and unplanned penetrations. A repair or panel substitution should retain the documented system; fitting a visually similar 75 mm module does not establish equivalent fire performance.

Planning your Fire-Rated Rock Wool Cleanroom Panel 75 mm Steel-Framed Fire-Resistant specification?

Send us your dimensions, installation conditions, performance targets and required surface finish.