zhengfeng-FIRE-RATED-CLEANROOM-DOOR-GRP-FRAME-SINGLE

Fire-Rated Cleanroom Door GRP-Frame Single-Leaf

An opaque vermiculite-core GRP leaf and GRP frame form a reference fire-door configuration requiring evidence for the selected complete assembly.
  • The opaque leaf omits a glazed penetration.
  • Concealed intumescent detailing avoids exposed strip ledges.
  • Matching molded frame surfaces maintain a consistent cleaning finish.
Request a Quote Browse Products

An opaque GRP-frame configuration for a specified fire boundary

This single-leaf configuration combines a 40 mm molded GRP blade, vermiculite core, matching GRP frame and concealed intumescent detailing. Its smooth gelcoat exterior and opaque face suit compartment entrances where a viewing panel is unnecessary. The mineral core and heat-responsive seals form parts of the fire-door design; their presence alone does not establish the finished door's rating.

The required fire classification, duration, permitted dimensions and supporting wall must be matched to evidence for the exact supplied doorset. No particular time rating or certification is established on this page. Use the selected assembly documents to determine whether it is suitable for the project's boundary before procurement.

Construction and performance schedule

ElementListed configuration and required decision
Leaf40 mm opaque GRP envelope with vermiculite core.
FrameGRP; frame depth, anchors and wall junction included in the assembly specification.
ActionSingle-action hinges with compatible closer and handle preparation.
Fire sealsConcealed intumescent construction; location and permitted alterations controlled by the selected design.
Smoke controlCompatible smoke-seal option; required leakage conditions and evidence specified separately.

Intumescent material responds to heat. It should not be assumed to act as the normal-temperature smoke seal or the cleanroom pressure gasket. These functions may need different components, all compatible with the documented door construction. Concealing the strip reduces exposed detail but does not permit cutting or drilling through its location.

Installation and operating reliability

Install into the wall type and opening arrangement allowed by the assembly documentation, with specified perimeter sealing and fixings. Hardware selection must include the required closing and latching behavior. A strong closer cannot correct a distorted frame or an incompatible gasket; assess normal room pressure while adjusting the operating cycle.

Keep the closing path unobstructed. Any hold-open or access-control equipment must be appropriate to the approved fire-door arrangement and its release sequence. Factory hardware preparation helps preserve reinforcement and concealed seals. Later modifications need assessment against the supplied documentation.

Acceptance, maintenance and quote scope

Price the documented door, frame, hardware, seals, wall interfaces, installation and commissioning as an assembly. At handover compare identification and supplied components with the approved schedule, check permitted gaps and demonstrate repeatable closure and latching. Inspect surface damage, hinge movement, seals and obstruction during routine service. A visual or functional site check does not create a fire rating for an undocumented door.

Planning your Fire-Rated Cleanroom Door GRP-Frame Single-Leaf specification?

Send us your dimensions, installation conditions, performance targets and required surface finish.

Talk to Our Team
Inquiry Form