Fire-Rated Cleanroom Door GRP-Frame Double-Leaf
- Paired blades divide a wider opening between two hinge lines.
- Opaque faces retain visual screening across the full entrance.
- The molded frame matches the cleanable finish of both leaves.
A paired GRP doorset for wider compartment access
Two opaque 40 mm molded GRP leaves with vermiculite cores meet within a matching GRP frame. Each leaf is supported at an outer jamb, dividing the width and swing geometry of a larger opening. The pair is intended to be specified as one fire-door assembly, including its meeting-edge seals, hardware and wall installation.
Evidence for a single leaf cannot automatically establish the rating of a pair. The required fire classification and duration must cover the selected two-leaf arrangement, permitted dimensions, frame, seals and hardware. This page does not establish a particular rating or certificate for the supplied configuration.
Define the daily and full-opening modes
| Item | Reference and procurement decision |
|---|---|
| Leaves | Two opaque 40 mm GRP blades with vermiculite cores and gelcoat faces. |
| Frame | Matching GRP, fixed to the wall arrangement covered by the assembly documents. |
| Action | Single-action hinged pair. |
| Fire-seal construction | Concealed intumescent detail, including the specified meeting-edge arrangement. |
| Options | Compatible paired closing hardware and smoke seals within the documented design. |
Set the active-leaf width for everyday access and the combined clear opening for occasional transfers. Equal leaves are not automatically the best layout, and the reference description does not establish whether equal or unequal sizes are supplied. The inactive leaf's securing method and any escape function must match the approved operating schedule.
Meeting edges and closing order
Where an overlapping meeting detail requires one leaf to close first, the closing system needs the corresponding sequence control. Test with both leaves open as well as with only the active leaf open. A pair that latches during one operating pattern may fail after a full-width transfer if the leaves return in the wrong order.
Intumescent seals respond to heat; smoke control and routine room-pressure leakage require their own compatible sealing arrangements. Do not substitute a generic brush or rubber strip at the centre joint. Keep the specified gaps and retention hardware intact when adjusting hinges or closers.
Installation, upkeep and acceptance
Support both jambs and the head without twisting the frame. Check the full floor sweep and required bottom clearances for both leaves. Inspect bolts, latches, coordinators where fitted, seals and frame movement during maintenance; clearing an obstruction or correcting sag is preferable to increasing closer power indiscriminately.
Quote both leaves, frame, complete paired hardware, seals, installation, documentation and any alarm-linked equipment together. Handover should verify assembly identity and permitted dimensions, demonstrate daily and full-opening closure sequences, and record specified gaps and latching under operating pressure. A successful site swing test supplements the fire documentation; it does not replace it.
Planning your Fire-Rated Cleanroom Door GRP-Frame Double-Leaf specification?
Send us your dimensions, installation conditions, performance targets and required surface finish.